ELT CODING PROGRAMMING, ID READER AND MAINTENANCE TEST
Important Note: These tests should be performed only within an RF Screen Room or
Facility providing shielding of RF Emissions.
1.
Setup
Use provided cable to connect the ELT (RJ-12 port) to the mini PC (USB port)
2.
ELT Coding Programming
2.1
Double-Click “AK451” Icon to run the program. The programming window
appears as below:
Figure 1
Note: If you don’t see the window above, you may try the other USB port.
2.2
Set the ELT main switch to “ARM” position.
2.3
Verify the LED ‘ON’ light illuminates for 4 seconds.
2.4
At the “:>_” prompt, type: cn Password command then press “Enter” to go to
main menu. Must type this command within next 20 seconds after the command
prompt appears.
Note 1: Please contact Ameri-King for Password, via Email or fax or call.
Note 2: If there is no programming command input in this time window, the ELT will enter the
Self-Test mode, and you cannot program the ELT. In this case, set the ELT switch to “OFF”
position and start again from step 2.2.