Dutchwest Non-Catalytic Convection Heater
30002314
Distance from Center of Flue Collar to Wall in Top-Exit Installations
Dutchwest Convection Heater Model 2477
NOTE: These are not clearance distances. These measurements indicate where the centerline of the flue col-
lar will be for various installations. Measurements are from the centerline of the flue collar to the wall, not the
wall protector.
ST427
dutchwest
flue centerline
6/30/00 djt
A
B
C
E
D
F
C
F
Chimney Connector
Side
Rear
Corner
Side
Rear
Corner
Listed, Approved
(A) 35”
(B) 13”
(C) 19⁵⁄₈”
(D) 21”
(E) 13”
(F) 19⁵⁄₈”
Double-wall, with
(889 mm)
(330 mm)
(499 mm)
(533 mm)
(330 mm)
(499 mm)
flue collar shield
Single wall, with
(A) 28”
(B) 12”
(C) 18⁵⁄₈”
(D) 19”
(E) 9”
(F) 16¹⁄₈”
Connector heat shields
(711 mm)
(305 mm)
(473 mm)
(483 mm)
(229 mm)
(410 mm)
and flue collar shield
Single wall with no
(A) 35”
(B) 22”
(C) 26⁵⁄₈”
(D) 19”
(E) 17”
(F) 22⁵⁄₈”
heat shields
(889 mm)
(559 mm)
(676 mm)
(483 mm)
(432 mm)
(575 mm)
UNPROTECTED SURFACES
PROTECTED SURFACES
Corner
Corner
Parallel Installations
Installations Parallel Installations
Installations