Specifications – American Access Systems Touch Plate Reader - 11-3500 User Manual
Page 12

Page 12 American Access Systems / Security Brands, Inc.
NEW FEATURES AVAILABLE ON
11-3500 VERSION 4.0 AND LATER.
REMOTE OPEN (REX)
Connect the Brown and orange wires to any Normally Open switch. Closing this circuit will activate the latch Relay/
Shunt Relay for the number of seconds you have selected when you set the Latch Timer.
SecuRelayTM
The SecuRelayTM from Secura Key may be purchased separately for use with ENTRACOMP® 26SA units which
have firmware version 4.0 or later. SecuRelayTM allows the lock/gate control circuit to be remotely located so that
attacking the 26SA will not open the passageway. SecuRelayTM comes with a wiring harness which plugs directly
into the 3-pin header on the 26SA circuit board (see figure 1) NOTE: Remote Open must be disabled if SecuRelayTM
is used.
SOLID STATE RELAY (Version 4.05).
See page 10 for programming the NEW solid state relay.
SPECIFICATIONS
POWER REQUIREMENTS
10 to 24 VAC, 70 mA , 50 or 60 Hz or 10 to 24 VDC, 70mA
OUTPUTS
Latch & Alarm Shunt
SPST contact, 1A up to 60 VAC or VDC
Tamper (optional)
SPDT contact, 115 VAC, 2A maximum
SecuRelayTM (optional)
3-wire data and power circuit
INPUTS
Remote Open (REX)
Close circuit to operate Latch Relay
ENVIRONMENT
Ambient Temperature
-40oF to 158oF (-40oC to 70oC)
Humidity
0% to 95% relative humidity (non-condensing)
OPERATIONAL
Memory
E² PROM (non-volatile)
Card Capacity
65,503 cards
Facility Code
Up to 10 different codes simultaneously
Latch/Alarm Shunt Timer
Programmable from 1 to 99 seconds
Timed Antipassback
Programmable from 1 to 99 minutes
This product complies with UL 294 standards.
TouchCard® and SecuRelay™ are trademarks of Secura Key.