Please read prior to installing this fan – Panasonic FV-08VKME3 User Manual
Page 4
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

PLEASE READ PRIOR TO INSTALLING THIS FAN________________
The WhisperGreen line of ventilating fans employs state of the art technology providing a number of
unique features that lead to improved indoor air quality. These features need to be fully understood
prior to installation to full realize the benefits fans offer.
Spot and Continuous Ventilation: These fans are designed to run continuously ensuring a healthy
environment at low CFM levels 24 hours a day. By utilizing Customvent variable speed control
the fans are built to run continuously at a pre-set lower level (0,30,40,50,60,70 CFM). The setting
is dependent on the size of the room and the individual wishes of the homeowner. It is crucial
that the installer pre-set the lower setting during the installation. Please refer to the
chart below and the switch indication on page 7.
CustomVent Variable Speed Control (Lower Setting).
ASHRAE 62.2-2007
(sq.feet)
Two Bedrooms Three Bedrooms Four Bedrooms
Five Bedrooms
< 1, 000
33
40
48
55
1,500
38
45
53
60
2,000
43
50
58
65
2,500
48
55
63
70
3,000
53
60
68
75
3,500
58
65
73
80
4,000
63
70
78
85
4,500
68
75
83
90
5,000
73
80
88
95
5,500
78
85
93
100
6,000
83
90
98
105
6,500
88
95
103
110
7,000
93
100
108
-
These fans are also built to take care of the homeowner's spot ventilation needs when the room is
occupied. This models kick-up to a maximum level of 80 CFM either when the switch is turned on
(available with FV-08VKSE3) or activated by the SmartAction Motion Sensor(available with
FV-08VKME3).
A High / Low Delay Timer, located inside the fan unit, is utilized to return the fan back to the pre-set
Continuous ventilation mode. The installer needs to consult with the homeowner for the desired
setting on the timer (0.5 - 60 minutes) and make the adjustments during the installation.
Optimum Ventilation Performance: Generally duct length, elbows and other factors increase static
pressure hindering the performance of most ventilation fans. This fan utilize SmartFlow microchip
technology that monitors the static pressure in the system and speeds up or slows down the rpm of the
fan depending on the amount of resistance. This allows the fan to perform as rated, whether facing
0.1,0.2 or even 0.25 inches water gauge. The bottom line is that it makes for easier installation.
The installer no longer has to worry about compromising the fan's performance.
Outstanding Energy Savings: These fans are the very first to be built using DC motor technology.
The new DC motor is 30% - 70% more energy efficient than the minimum ENERGY STAR requirements.