Clarion UNGO MS8200 User Manual
Page 27
MS8200 / MS8300 Installation Manual - Page 25
• During output testing, each function will stay active for as long as the transmitter
button is held.
After you have finished testing, turn off the ignition key to exit Real Time Installation
Verification.
Starter Defeat
Override Switch
Sensor Kill Wire
Hood/Trunk Input
Door
Optional Sensor Input
Warn Away Input
Door Closed Door Open
Function To Test
Response
Turn Key To Start Position
Press Override Switch
Ground Gray/black wire
Open Hood/Trunk
Open Door
Trigger Optional Sensor
Trigger Warn Away input
Vehicle will not start
LED Flashing
LED Solid
4 Chirps
1 Chirp
3 Quick Chirps
2 Quick Chirps
Input Test
Parking Lights
Dome Light
Door lock
Door unlock
Horn
Siren
Function To Test
Button 1
Button 2
Mode, 2
Mode, Mode, 1
Mode, Mode, 2
Mode, Mode, Mode, 1
Output Test
Any T
ime
installation_rev3.qxd 7/26/99 6:07 PM Page 25