beautypg.com

Chateau, Warning – CFM Corporation DVT38IN User Manual

Page 34

background image

34

Chateau™

20011956

Lighting & Operating Instructions

For Fireplaces equipped with American Flame Automatic Control System (IN or IP)

A. This fireplace is equipped with an ignition device

which automatically lights the pilot and main burner.
The pilot and burner light automatically with the hand
held remote control only. DO NOT try to light the
pilot by hand. Before lighting this appliance, follow
these instructions exactly.

B. BEFORE OPERATING, smell all around the

appliance area for gas. Be sure to smell next to
the floor because some gas is heavier than the air
and will settle on the floor.

What to do if you smell gas

• Do not try to light any appliance.

For Your Safety, Read the Following Warnings

before Lighting the Appliance

• Do not operate any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas suppliers
instructions.

• If you cannot contact your gas supplier call the

Fire Department

C. Do not use this appliance if any part has been under

water. Immediately call a qualified service technician
to inspect the appliance and replace any part of the
control system and any gas control that has been
under water.

1. Turn the wireless remote to the OFF position.
2. Turn OFF all electrical power to the fireplace if
service is required.
3. Turn the shut-off valve on the gas supply line to
the OFF position.

FP297A

Warning:

If you do not follow these instructions exactly, a fire or explosion may

result, causing property damage, personal injury and loss of life.

Lighting Instructions

Turning Off the Gas to the Appliance

1. STOP! Read the safety information above before

continuing.

2. Turn off all electrical power to the appliance.
3. This appliance is equipped with an ignition device

which automatically lights the pilot. DO NOT try to
light the pilot by hand.

4. Turn the wireless remote OFF.
5. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.
If you smell gas, STOP. Follow instruction B
in the safety warnings above. If you do not
smell gas, go on to the next step.

6. Turn ON all electrical power to the

appliance.

7. Turn wireless remote ON.
9. If the appliance will not operate, follow the

instructions TURNING OFF THE GAS TO
THE APPLIANCE, and call your service
technician or gas supplier.

FP297A

INSTA VENT FREE

UVHB26 GAS SUPPLY

7/1/98

1/2” Gas Supply

1/2” NPT X 1/2” Flare
Shut-off Valve

1/2” Gas Tight or
Tinned Copper
(from valve)
(Not provided)

������
������������
����

“S” Connection

Connect to Module

Spark to Pilot

Pilot Assembly

Pilot Gas

Connection Side or Back

“I” Connection

Connect to

Module

Main Valve Internal Solenoid

Connection

Green & White Wires

Pilot Internal Solenoid

Connection

Orange & White Wires

Pilot

Adjustment

Screw

Motor Wires

Black Plastic Cap

Minimum Rate
Screw

Motor Drive

This manual is related to the following products: