beautypg.com

7 | maintenance – GEA Bock HG12Р CO2 User Manual

Page 22

background image

22

D
GB
F
E

09917-02.2015-DGbFEI

7| Maintenance

7.5 Extract from the lubricants table

Only use genuine GEA Bock spare parts!

7.3 Spare parts recommendation

For operation with CO

2

the oil GEA Bock C 85 E is necessary!

7.1 Preparation

7.2 Work to be carried out
In order to guarantee optimum operational reliability and service life of the compressor,

we recommend

carrying out servicing and inspection work at regular intervals:

Oil change:

-

not mandatory for factory-produced series systems.

-

for field installations or when operating near the application limit: for the first time after 100
to 200 operating hours, then approx. every 3 years or 10,000 - 12,000 operating hours.
Dispose of used oil according to the regulations; observe national regulations.

Annual checks: Oil level, leak tightness, running noises, pressures, temperatures, function of
auxiliary devices such as oil sump heater, pressure switch.

WARNING! Before starting any work on the compressor:

Switch off the compressor and secure it to prevent a restart.

Relieve compressor of system pressure.

Prevent air from infiltrating the system!

After maintenance has been performed:

Connect safety switch.

Evacuate compressor.

Release switch-on lock.

Available accessories can be found on the Internet at www.gea.com

7.4 Accessories

HGX12P / ...

30-4 CO

2

40-4 CO

2

50-4 CO

2

60-4 CO

2

75-4 CO

2

Designation

Item No.

Item No.

Item No.

Item No.

Item No.

Set of gaskets

80372

Valve plate kit

80721

80369

Set piston/
connecting rod

80723

80585

80586

80370

80371

Set connecting rod

80724

80601

80368

80424