beautypg.com

4 | compressor assembly – GEA Bock HG12Р CO2 User Manual

Page 11

background image

D
GB
F
E

11

09917-02.2015-DGbFEI

Valve spindle seal

Release

Tighten

Fig. 13

Fig. 14

4| Compressor assembly

Before opening or closing the shut-off valve, release the valve spindle seal by approx. ¼ of a turn

counter-clockwise.

After activating the shut-off valve, re-tighten the adjustable valve spindle seal clockwise.

4.6 Operating the shut-off valves

Pipe connection

Pipe connection

4.7 Operating mode of the lockable service connections

Fig. 15

Opening the shut-off valve:
Spindle: turn to the left (counter-clockwise) as far as it will go.
—> Shut-off valve completely opened / service connection closed.

Fig. 16

Opening the service connection
Spindle: Turn ½ - 1 turn to the right clockwise.
—> Service connection opened / shut-off valve opened.

Service connec-
tion closed

Connection
blocked

Spindle

Service connec-
tion opened

Spindle

Connection
open

Compressor

Compressor

After activating the spindle, generally fit the spindle protection cap again and tighten with 14-16 Nm.
This serves as a second sealing feature during operation.