5 | electrical connection – GEA Bock HA5 User Manual

Page 16

background image

16

D
GB
F
E
I
Ru

09911-01.2015-DGbFEIRu

5| Electrical connection

400 V

Direktstart YY

Teilwicklungsstart Y/YY

1V1

1W1

1U1

2W1

2V1

2U1

L3

L2

L1

L3

L2

L1

L3

L2

L1

1V1

1W1

1U1

2W1

2V1

2U1

Direct start YY

Part winding start Y/YY

ATTENTION! Failure to do this results in opposed rotary fields and results in

damage to the motor. After the motor starts up via partial winding
1, partial winding 2 must be switched on after a maximum delay of
one second . Failure to comply can adversely affect the service life
of the motor.

The motor is wired for direct start (YY) at the factory. For part winding start Y / YY, the bridges must be
removed and the motor feed line connected according to the circuit diagram: