Flash code (no.of flashes) – Freerider FR510DXs2b(D,Land Ranger S) User Manual
Page 32
FLASH CODE
(No.of flashes)
Battery needs recharging
Battery voltage too low
Battery voltage too high
Current limit time out
Brake fault
Out of neutral when power
switched on at key switch
Speed pot error
(wig wag)
Motor volts error
Other internal error
STATUS FAULT CODES
The original manufacturer's settings for this Scooter are:
SPEED CONTROLLER SETTINGS
Warning: Performance adjustments should not be
made which could put the operator in a serious
situation of control or braking. Performance
adjustments should only be made by a person
fully trained and conversant with the
programming process and it's capabilities.
Warning: Incorrect settings could cause injury to
the Scooter operator and/or to bystanders, or
damage to the vehicle and/or surrounding
property.
The forward-reverse speed Controller (Fig 37
page 30) is a state-of-the-art microprocessor
designed to give smooth and safe operation. For
maximum performance, protection and
convenience the Controller is housed in a solid
die cast aluminium case situated under the rear
body cover.
The speed Controller, 'Dynamic' model
DS72KO1(Rhino 70amp) is programmed by
to obtain the maximum performance
and safety for your Scooter.
If in doubt consult your Scooter
Manufacture
SPEED CONTROLLER SETTINGS
Warning:
1 Flash
2 Flashes
3 Flashes
4 Flashes
5 Flashes
6 Flashes
7 Flashes
8 Flashes
9 Flashes
The battery voltage has dropped below 23.3 volts in neutral.
Recharge the batteries soon.
The battery voltage at Controller has dropped to 16.5 volts.
Check the battery condition and the connections.
The battery voltage at the controller is greater the 32 volts.
Check the battery condition and the connections.
Suspect a charger malfunction.
The Controller has detected a shorted or overworked motor.
Check the loom for shorts or check out the motor.
Contact your Service Agent.
Check the Freewheel Lever is fully engaged. Check the Park
Brake and wiring for open or short circuits. Contact your
Service Agent.
Return the speed lever to neutral. Re-adjust the speed lever
neutral if necessary. Consult your Service Agent.
Check speed pot wiring for open or short circuits. Speed pot
may not be correctly set up. Contact your Service Agent.
Motor or wiring is faulty. Contact your Service Agent.
Contact your Service Agent.
Driving still possible
Drive inhibited
Drive inhibited
Drive inhibited
Drive inhibited
Drive inhibited. Drive possible if
neutral selected within 10 secs.
Drive inhibited
Drive inhibited
Drive inhibited
FAULT DISPLAYED
BY PROGRAMMER
SCOOTER
CONDITION
COMMENT
168-3 168-3S
168-4 168-4S
510DX2 510DXs2
1
6
10
4
4
10
60
15
70
6
1
6
10
4
4
10
60
15
70
6
1
6
10
5
4
10
60
15
70
6
1
6
10
4
4
10
60
15
70
6
1
8
8
4
4
10
60
15
70
6
1
8
10
5
4
10
60
15
70
6
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
ON
SET-UP MENU DESCRIPTIONSETTINGS
Acceleration
Deceleration
Forward Speed
Reverse Speed
Reduce Speed
Buzzer Volume
Motor Resistance
Sleep Time
Maximum Current
Park Brake Delay
OPTION MENU DESCRIPTIONSETTINGS
Single-Ended Pot
Standard Speed Pot
Motor Reverse
Pot Reverse
Brake Checking
Load Compensation
Enable Sleep
Check for Slope
Current Limit Tim
168-4S2b
1
6
10
4
4
10
60
15
110
6
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
ON
32