0 assembly and connection – Checkline LS-9-12000 User Manual
Page 4
– 4 –
4.0 Assembly and Connection
Point the stroboscope at the object to be observed.
On the bottom of the stroboscope are 3 threaded
holes, which allow you to afix it to the equipment
to be observed or a stand (available as an option):
• Center = 1 x 1/4” threaded hole
• Right and left, with a total distance of
60mm = 2 x M5 threaded holes
The stationary stroboscope has two identical
assigned sockets (located on the back of the unit) for the combined input of trigger
signal and supply voltage. The assignment of plug contacts is shown in Figure 1.
CAUTION: Please make the
connections in accordance with the
wiring diagram (Fig. 1). The trigger
input is potential-free. The potential-
free input is suitable for PNP and
NPN signals. A matching plug for
these input sockets is included with
the stroboscope.
RECOMMENDATION: Use
shielded cable to connect the trigger
signal.
CAUTION: Do not trigger the
stroboscope with signals above
12,500 FPM.
4.1 Typical connection examples
Please take connection examples
from Figures 2 to 5. Note that you
will need optional accessories for
some of the examples (stationary
stroboscope, AC Adapter, sensor,
etc.)
Figure 2 Trigger signal from
optional stroboscope
control unit, supply
voltage from optional
AC Adapter.
+24V
ID-Pin
GND
In1
In2
Out
DIN 41 524
(EN 60130-9)
1
2
3
5
4
1
2
3
5
4
s
ta
tionar
y
s
trobo
s
cop
e
Plug A
Plug B
AC Adapter
In1 or In2 or Out
In1 or In2
StrobeControl
Figure 1
Figure 2
– 5 –
FIG. 3 Trigger signal and supply
voltage from external
equipment.
FIG. 4 Trigger signal from external
equipment, supply voltage
from optional AC Adapter.
FIG. 5 Trigger signal from
optional sensor, supply
voltage for strobe and
sensor from optional
AC Adapter.
The voltage is either supplied by the
strobe power supply unit (available
as an option) or the equipment being
observed.
NOTE: When using the LS-9-12000 stroboscope without a stroboscope control unit,
the stroboscope lashes with the trigger signal of the connected equipment. This signal
cannot be inluenced without a stroboscope control unit.
s
ta
tionary
s
trobos
c
op
e
Plug A
Machine
In1 or In2
Figure 3
s
ta
tionary
s
trobos
c
op
e
Plug B
Plug A
AC Adapter
Machine
In1 or In2 or Out
In1 or In2
Figure 4
st
a
tionar
y st
robo
s
cop
e
Plug B
Plug A
AC Adapter
Sensor
In1 or In2
In1 or In2 or Out