4.0 Assembly and Connection

Point the stroboscope at the object to be observed.
On the bottom of the stroboscope are 3 threaded
holes, which allow you to afix it to the equipment
to be observed or a stand (available as an option):

• Center = 1 x 1/4” threaded hole

• Right and left, with a total distance of

60mm = 2 x M5 threaded holes

The stationary stroboscope has two identical
assigned sockets (located on the back of the unit) for the combined input of trigger
signal and supply voltage. The assignment of plug contacts is shown in Figure 1.

CAUTION: Please make the
connections in accordance with the
wiring diagram (Fig. 1). The trigger
input is potential-free. The potential-
free input is suitable for PNP and
NPN signals. A matching plug for
these input sockets is included with
the stroboscope.

RECOMMENDATION: Use
shielded cable to connect the trigger
signal.

CAUTION: Do not trigger the
stroboscope with signals above
12,500 FPM.

4.1 Typical connection examples

Please take connection examples
from Figures 2 to 5. Note that you
will need optional accessories for
some of the examples (stationary
stroboscope, AC Adapter, sensor,
etc.)

Figure 2 Trigger signal from

optional stroboscope

control unit, supply

voltage from optional

AC Adapter.

+24V

ID-Pin

GND

In1

In2

Out

DIN 41 524

(EN 60130-9)

1

2

3

5

4

1

2

3

5

4

s

ta

tionar

y

s

trobo

s

cop

e

Plug A

Plug B

AC Adapter

In1 or In2 or Out

In1 or In2

StrobeControl

Figure 1

Figure 2

– 5 –

FIG. 3 Trigger signal and supply

voltage from external

equipment.

FIG. 4 Trigger signal from external

equipment, supply voltage

from optional AC Adapter.

FIG. 5 Trigger signal from

optional sensor, supply

voltage for strobe and

sensor from optional

AC Adapter.

The voltage is either supplied by the
strobe power supply unit (available
as an option) or the equipment being
observed.

NOTE: When using the LS-9-12000 stroboscope without a stroboscope control unit,
the stroboscope lashes with the trigger signal of the connected equipment. This signal
cannot be inluenced without a stroboscope control unit.

s

ta

tionary

s

trobos

c

op

e

Plug A

Machine

In1 or In2

Figure 3

s

ta

tionary

s

trobos

c

op

e

Plug B

Plug A

AC Adapter

Machine

In1 or In2 or Out

In1 or In2

Figure 4

st

a

tionar

y st

robo

s

cop

e

Plug B

Plug A

AC Adapter

Sensor

In1 or In2

In1 or In2 or Out