For Pro16 applications—connecting one Pro16 device to another—the Cat-5e cables used with your

Aviom products may be up to 500 feet (approximately 150 meters) in length between devices. For example,

connecting a Y1 console card from a Yamaha digital console to the A-N

et

I

N

on a D800 A-Net Distributor is

such a connection.

Pro16 A-Net Out

Pro16 A-Net In

Total Pro16 A-Net cable length: 500 feet (150 meters)

Passive

Coupler

Passive

Coupler

Pro16 A-Net Out

Pro16 A-Net In

Total Pro16 A-Net cable length: 500 feet (150 meters)

Pro16e A-Net Out

Pro16 or

Pro16e A-Net In

Total Pro16e A-Net cable length: 400 feet (122 meters)

Passive

Coupler

Passive

Coupler

Pro16e A-Net Out

Pro16 or

Pro16e A-Net In

Total Pro16e A-Net cable length: 400 feet (122 meters)

When using Pro16e—such as the A-N

et

o

ut

from an AN-16/i v.2 to any other Pro16 or Pro16e device—

Cat-5e cables may be up to 400 feet (approximately 122 meters) in length between compatible devices

due to the larger amount of data being transmitted to accommodate Pro16e’s higher channel count.

Pro16 A-Net Out

Pro16 A-Net In

Total Pro16 A-Net cable length: 500 feet (150 meters)

Passive

Coupler

Passive

Coupler

Pro16 A-Net Out

Pro16 A-Net In

Total Pro16 A-Net cable length: 500 feet (150 meters)

Pro16e A-Net Out

Pro16 or

Pro16e A-Net In

Total Pro16e A-Net cable length: 400 feet (122 meters)

Passive

Coupler

Passive

Coupler

Pro16e A-Net Out

Pro16 or

Pro16e A-Net In

Total Pro16e A-Net cable length: 400 feet (122 meters)

The maximum cable length specification applies to the total cable length between an A-N

et

o

ut

port on

one device and the A-N

et

I

N

port on the next A-Net capable device in your system.

Your cable length performance will be affected by a number of factors including the quality of the cables

used, and the number of passive devices such as cable couplers or passive wall panel interconnections in

use.

Stranded or solid Cat-5e cable may be used; stranded cable is easier to deploy on a stage while solid

core cable provides slightly better maximum distance performance. Solid core wire is typically used in

permanent installations in walls and across ceilings.

When using the optional SB4 System Bridge with Pro16 and Pro16e devices, the cable length specification

applies to the total cable length between the two active A-Net devices being connected with the passive

System Bridge, plus all cables. This is also true when using a passive inline coupler to extend cable lengths.

Pre-made cables in a variety of lengths and colors are available at most computer outlets. Cables may be

extended by using a simple passive device called an inline coupler to add length to existing cables (as long

as you do not exceed the specified maximum cable length). If you need a longer cable on occasion, this is

a simple solution. Note that the maximum cable length performance can be compromised by using inline

couplers or other passive connection devices.

This manual is related to the following products: