5. Use the dropdown menu labeled “Boot Config Serial Port” to select the virtual

COM port connected to your AW900R4 module. Note that the list is populated only

when EvkUtilityLite first starts. If you change your cable connection or plug in an-

other module, restart the utility to see the changes. Next click the “Get” button to

fetch the current configuration from the module.
6.

If you are satisfied with the module’s configuration and status, stop here. If

changes are needed, here is an explanation of the parameters that may be set on

the Boot Configuration page:

Radio Configuration

Meaning

AccessPoint/Subscriber

Unit

Buttons to select whether this module is the master or the client of the

group. Each RS-485 wireless link must have one Access Point master and up

to 16 Subscriber Unit clients.

Number of Subscriber

Units/Subscriber ID

A two digit number, leading zero required. For the Access Point, this should

be the number of Subscriber Units to be connected. Subscriber Units must be

numbered in sequence: “01”, “02”, etc.

Channel 00-12

The RF channel for the module. The frequencies corresponding to each chan-

nel are shown in the table on page 5. Choose “00” for automatic channel

selection or set “01” to “12” for a fixed choice.

Network Name

A 32-bit value (8 Hex digits, 0 to 9 and A to F) that must be the same for

the radio modules in the group. If you have multiple wireless RS-485 groups

operating in the same vicinity, give each a unique value.

AES Private Key

A 128-bit value (32 Hex digits) that must be the same for the radio modules

in the group. This key is used to encrypt the transmitted data and decrypt

the received data.

4. Run EvkUtilityLite.exe and you should see a window like this: