Windtura 750 maintenance instructions – Windy Nation Windtura 750 Wind Turbine Generator User Manual
Page 16

16
Windtura 750 Maintenance Instructions
(Warning: Never attempt to perform maintenance on a wind turbine on a windy day. Never approach
a wind turbine when the blades are spinning.)
Required Maintenance
Frequency
Notes
Grease pivot bar
Once a year
Steps 1 & 2 of Figure 6
Grease tower pipe
Once a year
Step 1a of Figure 3
Inspect blades for dents, chips
cracks.
Clean blades of any dirt or
debris.
Once a year
Replace blade(s) if structural
integrity is compromised
Inspect all fastener
connections
Once a year
Tighten fasteners if loose.
Replace fasteners if corrosion
is present
Inspect all electrical
connections
Once a year
Fix or replace as needed if
connection is bad or corrosion
is present
Recommended to replace 500
Watt generator bearings
For optimal performance, we
suggest to replace bearings
every 7-10 years.
Car mechanic shops are
capable of replacing bearings
Check tower angle is vertical
Twice a year
Re-align tower angle when
necessary