Spare parts, Troubleshooting – STIEBEL ELTRON Tempra 36 User Manual
Page 8

– 8 –
J
1
2
3
4
5
6
7
8
3
TEMPRA 22, 29 and 36 only
256126
/1
b
256126
/1
b
256126
/1
b
256126
/1
b
256126
/1
b
256126
/1
b
8834.03
8833.01
No. Spare part
Model TEMPRA 12 TEMPRA 15 TEMPRA 20 TEMPRA 22 TEMPRA 24 TEMPRA 29 TEMPRA 36
1 Heating system
26 65 84
26 90 25
24 91 58
26 90 25
26 65 84
24 91 58
26 65 84
2 Electronic control device: Master
26 47 17
3 Electronic control device: Slave
26 47 18
4 Safety thermal cut out
26 65 83
17 03 05
17 03 05
17 03 05
26 65 83
17 03 05
26 65 83
5 Flow sensor
26 65 85
6 Cold water connection
26 65 86
26 65 87
26 65 87
26 65 88
26 65 87
26 65 88
26 65 88
7 Warm water connection
26 65 90
26 65 91
26 65 91
24 91 68
26 65 91
24 91 68
24 91 68
8 Temperature adjustment knob
16 35 73
Spare parts
J
Troubleshooting
If you are not able to resolve a problem please contact us toll free at 800-582-8423 before removing the unit from the wall.
STIEBEL ELTRON is happy to provide technical assistance. In most instances, we can resolve the problem over the phone.
Symptom Possible
Cause
Solution
No hot water
Water not hot enough
LED displays one of the following fault codes:
91, 92, 93, 94, 95, 96, 97
– circuit breakers off
– safety thermal cut-out tripped
– not enough flow rate to activate unit
– water flow rate too high
– voltage too low
– problem with electronic control module
– turn circuit breakers on
– reset thermal cut-out
– clean filter screen at unit
– clean faucet aerator or shower head
– reduce water flow rate until light on front
cover stops blinking
– supply correct voltage to unit