Gpm l/min – STIEBEL ELTRON TEMPRA 12 B User Manual
Page 3

– 3 –
2. Table showing temperature increase above ambient water temperature
Maximum temperature increase above ambient water temperaturetLegend to figures
Warm water outlet temperature
140 °F
60 °C
TEMPRA 12 B / TEMPRA 12 Plus
@ 208 V
9 kW
0.61
0.76
0.97
1.36
2.27
6.61
2.30
2.86
3.68
5.16
8.59
25.00
@
220 -
240
V
12
kW 0.81 1.01 1.30 1.82 3.03 6.61 3.07 3.82 4.91 6.87 11.46
25.00
TEMPRA 15 B / TEMPRA 15 Plus
@ 208 V
10,8 kW
0.73
0.91
1.17
1.63
2.72
6.61
2.76
3.44
4.42
6.19
10.31 25.00
@
220 -
240
V
14.4
kW 0.97 1.21 1.56 2.18 3.63 6.61 3.68 4.58 5.89 8.25 13.75
25.00
TEMPRA 20 B / TEMPRA 20 Plus
@ 208 V
14.4 kW
0.97
1.21
1.56
2.18
3.63
6.61
3.68
4.58
5.89
8.25
13.75 25.00
@
220 -
240
V
19.2
kW 1.30 1.61 2.08 2.91 4.84 6.61 4.91 6.11 7.86 11.00
18.33
25.00
TEMPRA 24 B / TEMPRA 24 Plus
@ 208 V
18 kW
1.22
1.51
1.95
2.72
4.54
6.61
4.60
5.73
7.36
10.31 17.18 25.00
@
220 -
240
V
24
kW 1.62 2.02 2.59 3.63 6.05 6.61 6.14 7.64 9.82 13.75
22.91
25.00
TEMPRA 29 B / TEMPRA 29 Plus
@ 208 V
21.6 kW
1.46
1.82
2.33
3.27
5.45
6.61
5.52
6.87
8.84
12.37 20.62 25.00
@
220 -
240
V
28.8
kW 1.95 2.42 3.11 4.36 6.61 6.61 7.36 9.16 11.78
16.50
25.00
25.00
TEMPRA 36 B / TEMPRA 36 Plus
@ 208 V
27 kW
1.82
2.27
2.92
4.09
6.61
6.61
6.90
8.59
11.05 15.47 25.00 25.00
@
220 -
240
V
36
kW 2.43 3.03 3.89 5.45 6.61 6.61 9.21 11.46 14.73
20.62
25.00
25.00
Cold water inlet temperature
°F
°C
39 59 77 95 113 131 4 15 25 35 45 55
Warm water outlet temperature
113 °F
45 °C
TEMPRA 12 B / TEMPRA 12 Plus
@ 208 V
9 kW
0,83
1,14
1,70
3,41
6,61
3,14
4,30
6,44
12,89 25,00
@
220 -
240
V
12
kW 1,11 1,51 2,27 4,54 6,61
4,19 5,73 8,59 17,18
25,00
TEMPRA 15 B / TEMPRA 15 Plus
@ 208 V
10,8 kW
1,00
1,36
2,04
4,09
6,61
3,77
5,16
7,73
15,47 25,00
@
220 -
240 V 14.4 kW
1,33
1,82
2,72
5,45
6,61
5,03
6,87
10,31 20,62 25,00
TEMPRA 20 B / TEMPRA 20 Plus
@ 208 V
14.4 kW
1,33
1,82
2,72
5,45
6,61
5,03
6,87
10,31 20,62 25,00
@
220 -
240
V
19.2
kW 1,77 2,42 3,63 6,61 6,61
6,71 9,16 13,75
25,00
25,00
TEMPRA 24 B / TEMPRA 24 Plus
@ 208 V
18 kW
1,66
2,27
3,41
6,61
6,61
6,29
8,59
12,89 25,00 25,00
@
220 -
240 V 24 kW
2,21
3,03
4,54
6,61
6,61
8,38
11,46 17,18 25,00 25,00
TEMPRA 29 B / TEMPRA 29 Plus
@ 208 V
21.6 kW
1,99
2,72
4,09
6,61
6,61
7,54
10,31 15,47 25,00 25,00
@
220 -
240 V 28.8 kW
2,66
3,63
5,45
6,61
6,61
10,06 13,75 20,62 25,00 25,00
TEMPRA 36 B / TEMPRA 36 Plus
@ 208 V
27 kW
2,49
3,41
5,11
6,61
6,61
9,43
12,89 19,33 25,00 25,00
@
220 -
240 V 36 kW
3,32
4,54
6,61
6,61
6,61
12,57 17,18 25,00 25,00 25,00
Cold water inlet temperature
°F
°C
39 59 77 95 113 131 4 15 25 35 45 55
Warm water flow rate
GPM
l/min
Warm water outlet temperature
105 °F
40 °C
TEMPRA 12 B / TEMPRA 12 Plus
@ 208 V
9 kW
0,95
1,36
2,27
6,61
3,58
5,16
8,59
25,00
@
220 -
240 V 12 kW
1,26
1,82
3,03
6,61
4,77
6,87
11,46 25,00
TEMPRA 15 B / TEMPRA 15 Plus
@ 208 V
10,8 kW
1,14
1,63
2,72
6,61
4,30
6,19
10,31 25,00
@
220 -
240 V 14.4 kW
1,51
2,18
3,63
6,61
5,73
8,25
13,75 25,00
TEMPRA 20 B / TEMPRA 20 Plus
@ 208 V
14.4 kW
1,51
2,18
3,63
6,61
5,73
8,25
13,75 25,00
@
220 -
240 V 19.2 kW
2,02
2,91
4,84
6,61
7,64
11,00 18,33 25,00
TEMPRA 24 B / TEMPRA 24 Plus
@ 208 V
18 kW
1,89
2,72
4,54
6,61
7,16
10,31 17,18 25,00
@
220 -
240 V 24 kW
2,52
3,63
6,05
6,61
9,55
13,75 22,91 25,00
TEMPRA 29 B / TEMPRA 29 Plus
@ 208 V
21.6 kW
2,27
3,27
5,45
6,61
8,59
12,37 20,62 25,00
@
220 -
240 V 28.8 kW
3,03
4,36
6,61
6,61
11,46 16,50 25,00 25,00
TEMPRA 36 B / TEMPRA 36 Plus
@ 208 V
27 kW
2,84
4,09
6,61
6,61
10,74 15,47 25,00 25,00
@
220 -
240 V 36 kW
3,78
5,45
6,61
6,61
14,32 20,62 25,00 25,00
Cold water inlet temperature
°F
°C
39 59 77 95 113 131 4 15 25 35 45 55
En
gl
is
h