Installation technical data, Technical data, 1 dimensioned drawing – STIEBEL ELTRON DHC-E 12 User Manual
Page 8: 2 wiring diagram

8
| DHC-E
WWW.STIEBEL-ELTRON-USA.COM
INSTALLATION
TECHNICAL DATA
However, to ensure consistent water fl ow, it is recommended to
periodically remove scale and dirt that may build up at the aera-
tor of the faucet(s), the fi lter screen in the appliance, or in the
shower head.
10. Technical Data
10.1 Dimensioned
drawing
b01
c06
c01
c01
c06
38 (1.5")
360 (14.17")
200 (7.88")
100 (3.94")
110 (4.33")
273 (10.75")
75 (2.953")
8 (0.315")
D00000
17
76
2
b01 Electrical cable entry
c01 cold water inlet
"NPT
1/2
c06 hot water outlet
"NPT
1/2
10.2 Wiring
diagram
DHC-E 8/10
2/GRD ~ 208 / 240 V
1/N/PE ~ 220 / 230 / 240 V
85
_0
2_0
3
_0
0
01
DHC-E 12
2/GRD ~ 208 / 240 V
1/N/PE ~ 220 / 230 / 240 V
85
_0
2_0
3
_0
0
02