WARNING
Personal Injury Hazard.
I
Be careful when removing agitator. The belt tension Is high. Failure to do so could result
In personal Injury from agitator releasing quickly and snapping away.
Place the carpet/bare floor selector In the carpet position. Unplug and turn the unit over.
Remove the lower plate as described in the REMOVINC/ INSTALLING THE LOWER PLATE
section.
Remove the agitator, carefully lift it out, and remove the
worn or broken belt from the brush pulley and motor shaft.
NOTE:
The two brush supports may come off along with
the two washers as you lift the agitator out.
DO NOT
lose
the two small washers.
Loop the new belt around the motor shaft and loop it
around the brush pulley. See illustration for correct belt
routing.
Use only a Panasonic Type UBS drive belt.
Before reinserting the agitator make sure the brush sup-
ports/washers are on correctly. See illustration in
the REPLACING THE AGITATOR section.
After checking the brush supports, reinstall the agitator back into the housing grooves. After
installing the agitator, turn it by hand making sure that the belt is not twisted or pinched and all
rotating parts turn freely. Replace the lower plate as described in the REMOVING/INSTALLING
THE LOWER PLATE section.
*
Wim
THE
ag
№6
r
Switch off the vacuum cleaner and unplug the power
cord before cleaning the agitator. In order to keep the
cleaning efficiency high, clean the agitator regularly.
Remove the lower plate if necessary. See the REMOV
ING/! NSTALLING THE LOWER PLATE section
for the proper procedure.
Agitator - Cut off any carpet pile and lint
entangled around the agitator with a pair of
scissors as illustrated.
-
17
-