Other Programs (continued)
•
DISA Ringing Time Assignment
Sets the time to forward a call sent by the DISA
feature to other extensions. If the call is not
answered by the designated extension within the
programmed time, the call is forwarded to
extensions which are not assigned as “DIS
ABLE” in the #04/#74 COl Ringing Assignment
(Day/Night) and #05/#75 C02 Ringing Assign
ment (Day/Night). If “DISABLE” is selected in
this program, the telephone at the designated
extension rings for 60 seconds and the call is not
forwarded.
Input Format:
#60 [A]
• [A]=0: DISABLE /1:10 SEC/
2: 20 SEC (default)/ 3: 35 SEC
• Toll Restriction Code Check
Assigns whether “ ^ ” or “#” is to be checked or
not when a user dials them in the Toll Restriction
code.
Input Format:
#62 [A]
• [A]=0: DISABLE/ 1; ENABLE (default)
• CO Indicator Assignment
Assigns whether an incoming CO call indicates
or not on the CO button. Also it allows an
extension user to answer the call by pressing the
CO button when “DISABLE” is selected in the
#04/#74 “COl Ringing Assignment” or the #05/
#75 “C02 Ringing Assignment” program.
Input Format:
#63 [A]
• [A]=0: DISABLE (The indicator lights red and
a user cannot answer the
call.)
1: ENABLE (The indicator is flashing and
a user can answer the call.)
(default)
• Pulse Break Ratio Assignment
Assigns the pulse break ratio during dial pulsing.
Input Format.
#64 [A]
• [A]=l: 66% (default)/ 2: 60%
Hookswitch Flash Time Range
Assignment
Sets the hookswitch flash time range.
Input Format:
#65 [A]
• [A]=l: 80-1000ms (default)/ 2: 80-150ms
Dial Start Time
Sets the time the system waits before dialing
after a CO lined is seized.
Input Format:
#66 [A]
• [A]=l: 800 ms (default)/ 2: 2000 ms
Pulse Speed Selection
Sets the pulse speed for CO lines.
Input Format:
#68 [A]
• [A]=l: 10 EPS (default)/ 2: 20 PPS
Note
You cannot check the assignments of the above programs by setting the MEMORY switch to
“PROGRAM”, and entering “#” and the program address.