beautypg.com

Clarke C2K SERIES User Manual

Page 8

background image

Page -8 -

CLARKE TECHNOLOGY Operator's Manual - C2K Series 230V

230 VOLT MACHINES

Instruction for

connection to the power supply and the
electrical ground

.

CAUTION: This machine will operate

only on the AC frequency and electrical

voltage shown on the nameplate. Make sure

you have the correct frequency and voltage

before connecting the power cord to an

outlet.

This machine must be connected to the electrical

ground to protect the operator from electric

shock. The machine has a power cord with two

main conductors and one earthing conductor.

Connect the plug to the type of receptacle shown

in figure 4. The green and yellow conductor in the

cord is the ground wire. Never connect this wire

to any terminal other than the ground terminal.

WARNING: Always use this machine

with an AC three-conductor electrical

system connected to the electrical

ground. Replace any worn, cut, or

damaged cords. Replace any damaged

plugs, receptacles, or connector

bodies. Do not move the machine over

an electrical cord. Always lift the cord

over the machine.

EXTENSION CORDS

Use only an approved extension cord with two

main conductors and one earthing conductor.

The machine has a power cord with wire size 1.5

mm

2

.

WARNING: If you use an extension

cord, use an extension cord with minimum

wire size 1.5mm

2

. Do not use an extension

cord longer than 15 meters. Do not join two

extension cords.

WARNING: Do not cut, remove, or

break the ground terminal. Do not try to fit a

three- terminal plug into a receptacle or

connector body that does not fit the plug.

If the receptacle or connector body does not

fit the plug, see your Authorized person to

make the connection.

Figure 4

Pin Earthing Contact
(France and Belguim)

Shuko Plug

Side Earthing Contact
(German, Austria, The Netherlands,
Sweden,Norway, Finland, Portugal and
Spain)