10
Appendix
Leica DISTO™ A6 1.1.0 gb
D
GB
F
I
E
P
NL
DK
S
N
FIN
J
CN
RC
ROK
PL
H
RUS
CZ
Technical Data
255
Receiver signal too
weak, measurement
time too long,
distance > 100 m
Use target plate
256
Received signal too
powerful
Use target plate
(grey side)
257
Wrong measure-
ment, ambient
brightness too high
Use target plate
(brown side)
260
Laser beam inter-
rupted
Repeat measurement
Error
Cause
Remedy
Hardware error
Switch on/off the
device several times
and check if the
symbol still appears. If
so please call your
dealer for assistance.
Range
0.05 m to 200 m
0.2 ft to 650 ft
Power Range
Technology™
Measurements can be
made up to 100 m without
target plate
Measuring accuracy up
to 30 m (2
σ, standard
deviation)
typ.: ± 1.5 mm*
Smallest unit displayed
1 mm
Laser class
II
Laser type
635 nm, < 1 mW
InFo
Cause
Remedy
Ø laser spot (at
distance)
6 / 30 / 60 mm
(10 / 50 / 100 m)
Autom. switch off laser
3 min
Autom. switch off
instrument
6 min
Integrated telescopic
viewer
2x magnification
BLUETOOTH
®
2.0
9
Range of
BLUETOOTH
®
Cl. 2
min. 10 m
Display illumination
9
Integrated level
9
Multifunctional
endpiece
9
Timer
9
Single Measurement
9
Maximum, Minimum,
Continuous Measure-
ment
9
Historical storage of
20 values
Indirect Measuring
functions with Pytha-
goras
9
Storage of constant
9
Area/Volume calculation
with room calculations
9
Addition/Subtraction
9
Tripod thread
9
Battery life,
Type AA, 2 x 1.5V
up to 10 000