Dynon Avionics EMS-D10 Pilots Users Guide User Manual
Page 39

EMS Operation
7-6
EMS-D10 Pilot’s User Guide
Change power on alarms status: EMS > SETUP > GLOBAL > ALARM CONFIG > PWR ON ALARMS
Set this parameter to “ON” to enable alarms before engine startup. When set to “OFF”, all alarms are suppressed
whenever ALL of the following conditions exist:
RPM less than 400
Oil pressure less than 20 PSI
First five minutes after master instrument power applied
All alarms are enabled when any of the above conditions are exceeded.
Note: The alarm light (if installed and configured) will flash whenever an alarm condition exists; it is not inhibited by
setting PWR ON ALARMS to OFF.
Test light/audio alarm(s): EMS > SETUP > GLOBAL > ALARM CONFIG > TEST ALARM LIGHT/AUDIO
Note: You must select an alarm to test using the UP▲/ DOWN▼
buttons. Hold SEL► to test the selected alarm.
Info Item Configuration: EMS > SETUP > GLOBAL > INFO ITEM
CONFIG►
The INFO ITEM CONFIG submenu allows you to configure a variety
of different sensors as simple analog bars, on/off contacts, or text
items.
The first four info items are displayed on the EMS Main Page. Info
items 1 and 2 at the top and info items 3 and 4 at the bottom. The other
four info items are located on the Aux/Times Page and are numbered 5