beautypg.com

Dynon Avionics EMS-D10 Pilots Users Guide User Manual

Page 39

background image

EMS Operation

7-6

EMS-D10 Pilot’s User Guide

Change power on alarms status: EMS > SETUP > GLOBAL > ALARM CONFIG > PWR ON ALARMS

Set this parameter to “ON” to enable alarms before engine startup. When set to “OFF”, all alarms are suppressed
whenever ALL of the following conditions exist:

 RPM less than 400
 Oil pressure less than 20 PSI
 First five minutes after master instrument power applied

All alarms are enabled when any of the above conditions are exceeded.

Note: The alarm light (if installed and configured) will flash whenever an alarm condition exists; it is not inhibited by
setting PWR ON ALARMS to OFF.

Test light/audio alarm(s): EMS > SETUP > GLOBAL > ALARM CONFIG > TEST ALARM LIGHT/AUDIO

Note: You must select an alarm to test using the UP▲/ DOWN▼
buttons. Hold SEL► to test the selected alarm.

Info Item Configuration: EMS > SETUP > GLOBAL > INFO ITEM
CONFIG►

The INFO ITEM CONFIG submenu allows you to configure a variety
of different sensors as simple analog bars, on/off contacts, or text
items.

The first four info items are displayed on the EMS Main Page. Info
items 1 and 2 at the top and info items 3 and 4 at the bottom. The other
four info items are located on the Aux/Times Page and are numbered 5