2 installation, 1 safe handling of equipment with batteries, 3 safe operation – Dillon EDjunior (Old) User Manual
Page 6: Installation, Safe handling of equipment with batteries, Safe operation
6
EDjunior Dynamometer User Instructions
1.2 Installation
1.2.1 Safe handling of equipment with batteries
1.3 Safe Operation
Keep all the following in mind as you use the EDjr dynamometer.
The system capacity is equal to the rating of the dynamometers. The shackle rating
should not be used to determine lift capacity of the system.
Any zeroed deadload must be considered as part of the
ultimate load.
Although this instrument has a substantial overload protection rating, the instrument
should not be used above the rated capacity. Doing so can significantly impact fatigue
life of the instrument and cause premature and abrupt failure. If a higher capacity
reading is needed, Dillon insists that a larger instrument be used.
NOTE: This is a Note symbol. Notes give additional and important information, hints
and tips that help you to use your product.
DANGER: RISK OF ELECTRICAL SHOCK. NO USER SERVICEABLE
PARTS. REFER TO QUALIFIED SERVICE PERSONNEL FOR SERVICE.
CAUTION: Danger of explosion if battery is incorrectly replaced. Replace only
with the same or equivalent type recommended by the manufacturer. Dispose
of used batteries according to the manufacturer’s instructions.
ATTENTION: Il y a danger d'explosion s'il y a remplacement incorrect de la
batterie, remplacer uniquement avec une batterie du même type ou d'un type
équivalent recommandé par le constructeur. Mettre au rebut les batteries
usagées conformément aux instructions du fabricant.
DANGER: IF YOU OVERLOAD THIS DYNAMOMETER YOU COULD
SUFFER SEVERE INJURIES OR DEATH. THE TOTAL LOAD ON THE
DYNAMOMETER SHOULD NEVER EXCEED THE RATED CAPACITY.