Flight timer, Flight timer -7 – BendixKing KT 74 User Manual
Page 13

KT 74 Pilot's Guide
D201308000036
Operation
Rev 0 Dec 2013
Page-1-7
©
Honeywell International Inc. Do not copy without express permission of Honeywell
Table 1-1: FUNC Sequence with Squat Switch Input Enabled
Airborne/
Ground
GPS
INPUT
SEQUENCE
Airborne
Yes
PWR ON (Squawk) -> Flight Time -> Timer
-> ADS POS -> Edit Flight ID -> Alt Monitor
-> Squawk
Airborne
No
PWR ON (Squawk) -> Flight Time -> Timer
-> Edit Flight ID -> Alt Monitor -> Squawk
On
Ground
Yes
PWR ON (Squawk) -> Flight Time -> Timer
-> ADS POS -> Edit Flight ID -> Squawk
On
Ground
No
PWR ON (Squawk) -> Flight Time -> Timer
-> Edit Flight ID -> Squawk
Table 1-2: FUNC Sequence without Squat Switch Input Enabled
GPS
INPUT
SEQUENCE
Yes
PWR ON (Squawk) -> Flight Time -> Timer ->
ADS POS -> Edit Flight ID -> Alt Monitor -> Squawk
No
PWR ON (Squawk) -> Flight Time -> Timer ->
Edit Flight ID -> Alt Monitor -> Squawk
Each function is described in more detail below:
Flight Timer
Press the FUNC button once to display the Flight Timer. The Flight
Timer records the time for which the transponder has been powered
on and operating in flight mode – either ON or ALT.