SECT.

III

PAGE

4

0707

Litho in U.S.A.

Right - 6”, Left - 6”, Rear - 6” (12”
on control side if adjoining wall
or equipment is over 30” high for
service acess)

For use in non-
combustible locations.

Contact factory for
variances to clearances.

1 1/2” NPT common drain.
Do not connect other units
to this drain.
Do not use PVC pipe for
drain.

Each compartment has capacity for:

Three, 12˝ x 20˝ x 2

1

2

˝ or six, 12˝ x 20˝ x 1˝ deep

Cafeteria Pans.

WATER QUALITY REQUIREMENT

The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours of
use per day, and a Daily Blowdown, are as follows:

TOTAL DISSOLVED SOLIDS

less than 60 parts per million

TOTAL ALKALINITY

less than 20 parts per million

SILICA

less than 13 parts per million

pH FACTOR

greater than 7.5

CHLORINE

less than 30 parts per million

Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals. The
use of highly mineralized water will mean that more
frequent servicing of the steam generator will be necessary.
The fact that a water supply is potable is not proof that it will
be suitable for the generator.

ALLOW 6.00" MIN CLEARANCE

FROM REAR AND SIDES IN

NON-COMBUSTABLE LOCATIONS

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL, NSF and CSA (AGA, CGA).

5.0 Amps