Troubleshooting – V.I.O. Stream User Manual
Page 74

STREAM User Manual
74
Camera Access
Accessing the stream is as simple as connecting to its Wi-Fi signal and sending it commands through a browser or
the HTTP/XML interface. This open interface also means that if you are on a shared network, anyone else with
access to your local network can also connect to your camera and view your streaming video or send commands.
To help protect access to the camera, we have provided a user id and password. Once the user id and password
are set, all requests to the camera must first be authenticated. Removing the user id and password are as simple as
entering an empty string for the user id and password. In addition, if you are using Wi-Fi, you may wish to change
the default password to something you create, however, once this is done, you will need to remove your Wi-Fi
camera profile and re-connect with the new password.
Battery Choices
The STREAM battery end cap uses a rechargeable Lithium Ion battery. It is a 3.7 Volt, 1800 mA battery and it
should be used only with a compatible battery charger. It is designed to last roughly 2 hours of battery life,
however, this will vary based on settings (higher resolution and data rate will have lower battery life). Please
contact us if you have other battery life needs. Other batteries may be used with the USB end cap. Many USB
batteries are available commercially. The STREAM should work with batteries that have a 5V, 600 mA to 2
Amp Output.
Each type of battery has advantages and disadvantages when used in the STREAM. The camera battery level
indicators have been tailored to the battery provided in the battery end cap so other commercial batteries
would need evaluation for battery level detection/reporting.
As with all Lithium batteries, the STREAM’s Lithium Ion battery has a limited temperature range.
Battery Details:
Rated battery voltage: 3.7 V
Rated capacity: 1800 mAH
Limited charge voltage:
4.2 V
Charge time: 6 Hours
Standard charging: 0.2C, 360 mA
Max Charge Current:
1800 mA
Max discharge current
Continuous:1800 mA
Charging temperature: 0~45℃
Discharging temperature: -10~60℃
Weight: Approx 40 g
Cycle life: 300 times, capacity≥80%
Troubleshooting
USB device not recognized
If you are using a STREAM with the USB end cap, and it is not being recognized, please check the following items:
Is the RNDIS/Ethernet gadget driver set up properly to talk to 172.16.197.198 in your network settings?
Is your STREAM connected to the USB 2.0 port and powered on (remember to wait about 25 seconds
after power on to try to access the STREAM and access it via 172.16.197.197).