Hxjz-878 parameters setting, 1) parameters default value, 2) channel and frequency list – Hexin Technology HXJZ-878 10km-20km Middle Power RS-232/RS-485/TTL to RF Wireless Module User Manual
Page 6

HXJZ-878
RF
Data
Radio
User’s Manual
HXJZ-878 parameters setting
HXJZ-878 have one interface of TTL、
RS232、
RS485, You must specify the interface when you order. HXJZ-
878
main parameters: COM baud rate and verify,RF baud rate, Channel and frequency。
You
can
change
these
parameters
by
our
RF
Module
software.
When
RF
baudrate
is
faster
than
COM baudrate,One frame Can transmit limitless data. When RF baudrate is not faster than
COM baudrate
,One frame Can transmit 255 bytes. You can set the rate according your request.
Two HXJZ-878 communication must have conditions as follows:
1. Their channels (i.e.
frequency) is same.
2. Their RF rates is same.
3. RF Module Com baud rate and verify is agree with its equipment or PC that it connects with.
1) Parameters default value:
Channel: 1
Interface speed rate:9600BPS
Interface verify:none
Speed rate in air:9600BPS
2) Channel and frequency list
Channel
Frequency
Channel
Frequency
1
430.2000MHZ
9
458.5250MHZ
2
431.4288MHZ
10
459.1250MHZ
3
431.7360MHZ
11
459.5250MHZ
4
430.5072MHZ
12
460.1250MHZ
5
434.6940MHZ
13
460.5250MHZ