beautypg.com

Hexin Technology HXJZ-878 10km-20km Middle Power RS-232/RS-485/TTL to RF Wireless Module User Manual

Page 5

background image

HXJZ-878

RF

Data

Radio

User’s Manual

2HXJZ-878 Interface define:

1User interface:

HXJZ-878 have one interface of TTL/RS232/RS485, user can choose one

Item no

PIN

Description

User terminal

Remarks

1

Null

2

TXD/A

Serial data transmitting end

RXD/ A (RS-485)

3

RXD/B

Serial data receiving end

TXD/ B (RS-485)

5

GND

Ground

DGND/AGND

4,6,7,8,9

Null

Item no

PIN

Description

Level

Connected

to the terminal

User terminal

Remarks

1

GND

Ground

2

+12V

+12V DC

9-15V DC

Standard: 12V

Remarks: To avoid to connect the interface reverse and can not communicate, please check and assure the

voltage of 3 and 4 pin is existing by using multimeter. If there is one pin that has the voltage, another has not

voltage, which means the interface is connected reverse, please change the connection wires between pin 3

and 4.

2Power supply

HXJZ-878 power supply is 9-15V DC,Representative value is +12V DC,the current greater than 3A。

It

can

also

share power

supply

with

other

equipment,

however,

the

high

quality power

supply

with desirable ripple factor should be selected.

In addition, the reliable grounding must be used if there is other device in the system equipment. In case

of failure to connect with the earth, it can form its own grounding, but it must be absolutely separated from the

municipal electric supply.