background image

HXJZ-873 Mini Power Wireless Module User’s Manual

(Remarks: Jack space between is 2.0 mm.)

Definition of connecting pins and connection method:

Item no

PIN

Description

Level

Connected

to the terminal

User terminal

Remarks

1

SLE

Sleep control (input) end

Low level to sleep, High

level awake

2

TXD/ A (RS-485)

Serial data transmitting end

RXD/ A (RS-485)

3

RXD/ B (RS-485)

Serial data receiving end

TXD/ B (RS-485)

4

GND

Power supply/Ground

DGND/AGND

5

VCC

+5±

0.5V

+5±

0.5V

TTL 3V user’s choose

6

I

2

NO. 2

on-off input

user terminal on-off output

7

I

1

NO. 1

on-off input

user terminal on-off output

8

O

2

NO. 2

on-off output

user terminal on-off input

9

O

1

NO. 1

on-off output

user terminal on-off input

User’s equipment

+5v regulator n. power supply

transmitter-receiver

Remarks:

To avoid to connect the interface reverse and can not communicate, please check and assure the voltage of 2

and 3 pin is existing by using Multimeter. If there is one pin that has the voltage, another has not voltage,

which means the interface is connected reverse, please change the connection wires between pin 2 and 3.

2) Power supply

HXJZ-873 uses DC power supply with voltage of +5V. It can also share power supply with other

equipment, however, the high quality power supply with desirable ripple factor should be selected. In addition,

the reliable grounding must be used if there is other device in the system equipment. In case of failure to

connect with the earth, it can form its own grounding, but it must be absolutely separated from the municipal

electric supply.

3) Application of IO control