Troubleshooting, Symptoms probable cause corrective action – Night Optics Magnus 790 6x Night Vision Riflescope (Gen. 3 Gated) User Manual
Page 10
9
NIGHT VISION
TROUBLESHOOTING
Image dimmer than usual.
SYMPTOMS
PROBABLE CAUSE
CORRECTIVE ACTION
No visible Image
a. Objective lens cap not
been removed.
b. Battery cover is loose.
c. Incorrect battery polarity
d. Weak battery
a. Remove cap
b. Tighten cover
c. Reinsert battery
d. Replace battery
Image flickers, flashes, or
clicking is heard
a. Normal for new battery to
cause this for first five minutes.
a. If condition continues
contact manufacturer for
service instructions
Dark spots on screen
a. Cosmetic blemishes. Normal
for this technology.
a. Acceptable as long as it
does not interfere with
operation of the device
Image not clear
a. Focus is not adjusted.
b. Too close to object
a. Adjust focus
b. Increase viewing distance.
Fixed pattern noise. (honey-
comb)
a. Cosmetic blemishes caused
by too much illumination.
a. Acceptable as long as
target resolution can be
resolved.
Pattern of dark thin lines
(chicken wire)
a. Normal under worst
conditions. These lines will form
hexagonal or square
wave-shaved lines.
a. Weak batteries
b. Low natural illumination level.
a. Acceptable as long as it
does not interfere with
operation of the device
a. Replace the batteries.
b. Turn on IR illuminator.