beautypg.com

Maintenance, Warning – Bradford White S-2-100T6BN User Manual

Page 22

background image

22

General Operation continued-







MAINTENANCE

The following maintenance should be performed by a qualified service technician at the
minimum periodic intervals suggested below. In some installations, the maintenance
interval may be more frequent depending on the amount of use and the operating
conditions of the water heater. Regular inspection and maintenance of the water
heater and vent-air intake system will help to insure safe and reliable operation.

1

.

Annually check the operation of the thermostat.

2. The flow of combustion and ventilation air MUST NOT be restricted. Clear the

combustion air openings of any dirt, dust, or other restrictions. WARNING! The
ventilation air system may be HOT.

3.

At all times keep the water heater area clear and free from combustible materials,
gasoline and other flammable vapors and liquids.

4. Bi-annually conduct a visual check of the main and pilot burner flames to

determine that they are burning properly. See Burner Flame Check section.

5. Annually remove the inner door and main burner assembly to clean orifices and

related parts of any dirt or other foreign material. Inspect the burner ports for
obstructions or debris and clean with a wire brush as needed. Wire brush and/or
vacuum clean the combustion chamber as needed to remove scale deposits and
debris. NOTE: It is imperative for proper operation of the water heater that the
inner door be replaced in the original location.

WARNING

Water heaters are heat producing appliances. To avoid damage or injury there shall
be no materials stored against the water heater or vent-air intake system, and proper
care shall be taken to avoid unnecessary contact (especially by children) with the
water heater and vent-air intake system. UNDER NO CIRCUMSTANCES SHALL
FLAMMABLE MATERIALS, SUCH AS GASOLINE OR PAINT THINNER TO BE
USED OR STORED IN THE VICINITY OF THIS WATER HEATER, VENT-AIR
INTAKE SYSTEM OR IN ANY LOCATION FROM WHICH FUMES COULD REACH
THE WATER HEATER OR VENT-AIR INTAKE SYSTEM.

IMPORTANT

The water heater should be inspected at a minimum annually by a qualified
service technician for damaged components and/or joints not sealed. DO
NOT operate this water heater if any part is found damaged or if any joint is
found not sealed.