Thermistor Wire Testing

Step 1. Disconnect and unplug the solar control.

Step 2. Disconnect the thermistor twisted pair from the control or control sensor wiring.

Step 3. Connect a multimeter set to read ohms to the twisted wire stripped ends.

Determine the resistance value of the attached thermistor. NOTE: The

thermistor is field supplied and various

thermistors have different ohm values

for different temperatures. Refer to the

temperature specification sheet for the

thermistor installed on the water heater

to determine if the resistance value is

correct.

The image to the side shows a

resistance value for a thermistor at

ambient temperature connected under

the lower access cover (brown twisted

pair). The same procedure can be

followed to determine if the upper

thermistor value is correct.

Step 4. If the multimeter indicates a resistance that does not match the actual

temperature of the thermistor, replace the thermistor. Reconnect the wiring,

verify that the new thermistor does match, and reconnect to the solar control.

Turn on the power to the solar control.

If the multimeter indicates a short or open, disconnect the thermistor from the

connection made under the access cover. Measure the thermistor ohm value

directly. If the multimeter indicates an open, replace the thermistor.

If the multimeter indicates an appropriate ohm value, determine which wire is

open by measuring directly from one end of the wire to the other, or if short;

verify by measuring both wire ends from the same location. If the wiring

cannot be fixed, the wiring for the thermistor may have to be ran on the

outside of the water heater. Replace the wiring, and reconnect it to the solar

control. Turn on the power to the solar control.