beautypg.com

Installation instructions, Notice – Bradford White IGI-180R-10N User Manual

Page 33

background image

33

Installation Instructions

Everhot Horizontal Discharge Vent System

Identify the vent location

Figure 32

Steps:
- Place horizontal discharge adapter on water heater
- Mark position on wall
- Or use template provided with water heater
- Cut hole, covering the top of the water heater to prevent debris from entering


Measure dimension to fit

Figure

34

Figure 33

NOTICE

Note: if the vent system is shorter than 5 ft. (1,52 m) and no condensate collector is installed, be
sure to install the wall terminal with a 1° angle to the outside of the building.

NOTICE

Note: 3.5” (90 mm) is the minimum outer cap length. If needed the length outside the wall may
exceed this dimension.