Bradford White U-4-XRTW65T6FRN User Manual
Page 5
5
PARTS LIST
(Continued)
PART NAME AND DESCRIPTION
1. Blower Assembly
17. Drain Valve
2. Temperature Switch
18. Gas Valve
3. Pressure Switch
19. Thermal Well
4. Jacket Head Pan
20. Wire Harness
5. Jacket
21. Radiant Burner
6. Outer Door
22. Orifice
7. Mag. Anode- Hot Water Outlet
23. Manifold Mount
8. Flue Baffle Assembly
24. High Temp. Limit Switch
9. Dip Tube-Cold Water Inlet
25. Gas Feedline to Burner
10. Temp. & Pressure Relief Valve
26. Gas Feedline to Pilot
11. Glass Lined Tank
27. Spark Igniter
12. Flue Reducer
28. Mounting Plate
13. Combustion Chamber Assembly
29. Pilot Assembly
14. Jacket Base Pan
30. Flammable Vapor Sensor
15. Inner Door Gasket
31. Flam. Vapor Sensor Clip
16. Inner Door Assembly
32. Dilution Air Clip
(Replaces pg. 44 (238-45637-00) or pg. 40 (238-48933-00) in
instruction manual.)
THE FOLLOWING INSTRUCTIONS ARE FOR INSTALLATION OF:
GAS WATER HEATERS SUITABLE FOR WATER (POTABLE)
HEATING AND SPACE HEATING
1. All piping components connected to this water heater for space heating
applications must be suitable for use with potable water. In Massachusetts,
space heating piping length must not exceed 50 feet (15.24 meters).
2. Toxic chemicals, such as those used for boiler treatment, must not be
introduced into potable water used for space heating.
3. This water heater must not be connected to an existing heating system or
component(s) previously used with a non-potable water heating appliance.
4. When the system requires water for space heating at temperatures higher
than required for other means, such as an ASSE approved mixing valve
must be installed to temper the water for those uses in order to reduce the
scald hazard potential.
Please refer to the illustrations on the following pages for the suggested piping
arrangements.