beautypg.com

Figure 1 direct vent terminal clearances – Bradford White DS1-50S6FSX User Manual

Page 2

background image

2

Figure 1

Direct Vent Terminal Clearances

Canadian

Installations

1

US

Installations

2

A=

Clearance above grade, veranda, porch, deck or balcony

12 inches (30.5 cm) 12

inches

(30.5 cm)

B=

Clearance to widow or door that may be opened

12 inches (30.5 cm) 9

inches

(23 cm)

C=

Clearance to permanently closed widow

*b

*b

D=

Vertical clearance to ventilated soffit located above the
terminal within a horizontal distance of 2 feet (61 cm) from
the center line of the terminal

12 inches (30.5 cm)*a

12 inches (30.5

cm)*a

E=

Clearance to unventilated soffit

12 inches (30.5 cm) *a

12 inches (30.5 cm)

*a

F=

Clearance to outside corner

*b

*b

G=

Clearance to inside corner

*b

*b

H=

Clearance to each side of center line extended above
meter/regulator assembly

3 feet (.9 m) within a height

15 feet (4.6 m) above the

meter/regulator assembly

*b

I=

Clearance to service regulator vent outlet or oil tank vent

36 inches (91 cm) *b

J=

Clearance to non-mechanical air supply inlet to building or
the combustion air inlet to any other appliance

12 inches (30.5 cm) 9

inches

(22.8 cm)

K=

Clearance to a mechanical air supply inlet

6 feet (1.8 m)

3 feet (.9 m) above if

within 10 feet

horizontally

L=

Clearance above paved sidewalk or paved driveway
located on public property

7 feet (2.1 m)† *b

M=

Clearance under a veranda, porch, deck, or balcony

12 inches (30.5 cm)‡ *b

1

In accordance with the current CAN/CGA-B149 Installation Codes.

2

In accordance with the current ANSI Z223.1-(Latest edition)/NFPA 54 National Fuel Gas Code.

† A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single-
family dwellings and serves both dwellings.
‡ Permitted only if a veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the
floor.
*a) A minimum clearance value determined by testing in accordance with section 2.20.
*b) “Clearance in accordance with local installation codes and the requirements of the gas supplier”.

This manual is related to the following products: