TROUBLESHOOTING CHART (CONTINUED)

LED Status

Control Status

Probable Cause

Two flashes and three
second pause.

Weak pilot flame
detected. System will
reset when pilot flame is
sufficient.

1. Unstable pilot.
2. Pilot tube blocked or

restricted.

Three flashes and three
second pause.

Insufficient water
heating. System will
reset.

1. Thermowell sensor out of

calibration.

2. Possible

short.

Four flashes and three
second pause.

Excessive tank
temperature. System
must be reset.

1. Thermowell sensor out of

calibration.

2. Faulty

gas

valve.

Five flashes and three
second pause.

Thermostat well fault.

1. Damage to the thermowell

wire.

2. Thermowell

sensor

resistance out of range.

3. Replace thermowell.
4. If

thermowell

replacement

does not correct the
problem; Verify control is not
wet or physically damaged

5. Turn set point knob to "OFF"

position. Turn set point knob
to "PILOT" position and light
pilot.

6. Replace gas valve if five

flash error persists.

Seven flashes and three
second pause.

Gas valve electronic fault
detected.

1. Verify control is not wet or

physically damaged.

2. Turn set point knob to "OFF"

position. Turn set point knob
to "PILOT" position and light
pilot.

3. Replace gas valve if seven

flash error persists.

Eight flashes and three
second pause

False pilot flame present.

1. Pilot valve stuck in open

position

2. Turn set point knob to "OFF"

position. Turn set point knob
to "PILOT" position and light
pilot.

3. Replace gas valve if eight

flash error persists.