TROUBLESHOOTING CHART (CONTINUED)

LED Status

Control Status

Probable Cause

Six flashes and three
second pause.

Water leak detected by
accessory module (some
models).

Excessive amount of water in drain
pan/water dam.

Seven flashes and three
second pause.

Gas valve electronic fault
detected.

1. Verify control is not wet or

physically damaged.

2. Turn set point knob to "OFF"

position. Turn set point knob
to "PILOT" position and light
pilot.

3. Replace gas valve if seven

flash error persists.

Eight flashes and three
second pause.

False pilot flame present.

1. Pilot valve stuck in open

position.

2. Turn set point knob to "OFF"

position. Turn set point knob to
"PILOT" position and light pilot.

3. Replace gas valve if eight flash

error persists.