beautypg.com

Internet version for reference only – Bradford White M-I-60T6FSX User Manual

Page 25

background image

25

13. Fiberglass Insulation

27. Pilot Assembly

14. Outer Door (Varies by Model)

28. Steel Burner (Varies by Model)

THE FOLLOWING INSTRUCTIONS ARE FOR INSTALLATION OF:

GAS WATER HEATERS

SUITABLE FOR WATER (POTABLE) HEATING AND SPACE

HEATING

1. All piping components connected to this water heater for space heating

applications must be suitable for use with potable water. In Massachusetts,
space heating piping length must not exceed 50 feet.

2. Toxic chemicals, such as those used for boiler treatment, must not be

introduced into potable water used for space heating.

3. This water heater must not be connected to an existing heating system or

component(s) previously used with a non-potable water heating appliance.

4. When the system requires water for space heating at temperatures higher

than required for other means, such as an ASSE approved mixing valve
shall be installed to temper the water for those uses in order to reduce the
scald hazard potential.


Please refer to the illustrations for suggested piping arrangements.

INTERNET VERSION FOR REFERENCE ONLY