beautypg.com

Using the logic outputs, System block diagram and specification – Allen&Heath DR Switch User Manual

Page 4

background image

DR-switch User Guide AP4493

4

Using the Logic Outputs

System Block Diagram and Specification

+10V

G

20 19 18 17

G

21

22

23

24

V

+ -

G

13

+ -

14

+

-

15

+

-

16

GROUND

OUT

IN

DR-LINK

DC REFERENCE

VOLTAGE

INTERNAL POWER

9-16

1-8

9-12

5-8

1-4

+10V

2K2

CONTROL

CHAIN

OPTO-ISOLATED SWITCH INPUTS 1-24

OPTO-ISOLATED LOGIC OUTPUTS 1-16

OPEN COLLECTOR

Connectors:

Pluggable Phoenix 10way terminal

Switch Inputs:

Opto-isolated via 2k2 from +10V
Switch closure connects pin to ground (5mA)
Switch cable resistance up to 1k ohm

Logic Outputs:

Opto-isolated open-collector
Floating collector (+) and emitter (-) pins
Internal 10V DC source (500mA total max)
External DC source (+24V 200mA each max)

Communication:

DR-link serial port using RJ45 connectors
Uses Allen & Heath DR-link protocol
2m CAT5 STP cable supplied, maximum 300m
Requires adapter card fitted to DR SysNet port
Daisy chain up to 3 units

Configuration:

Configure with WinDR operating software
Requires V2.11 or greater
Separately configure switches and output
Latched, press, release, time of day action

System:

DR128 8 switch
DR66

12 switch, 4 logic

DR-switch adds 24 switch, 16 logic

Power Supply:

Universal mains input 100-240V.AC
Independent 10V supply for connections
500mA total available

Dimensions:

Rack 482.5 x 143 x 44 mm (1U)
Desk 442.5 x 141 x 48 mm

The output is opto-coupled to isolate the DR-
switch
from the connected equipment. It
provides an open collector output with floating
collector (+pin) and emitter (-pin).

Each 10way connector provides 4 open
collector pairs as well as an internal +10V DC
supply and ground pins. Do not use the
chassis ground screw which is for cable
shielding and safety earthing only.

The output may be used in many ways to
satisfy a wide range of interfacing applications.
It is important that the installer has a good
working knowledge of open collector and
interfacing circuits. Incorrect application may
result in damage to these outputs.

The internal +10V supply may be used as the
power source for low current applications such
as turning on LEDs, lamps and small relays.
One cable can feed the common supply or
ground to a bank of outputs.

Maximum current drawn from the

+10V supply for all outputs combined must not
exceed 500mA. Care must be taken in
component choice to ensure each operates
within its specified capability.

For higher current or voltage applications an
external DC power supply may be used. This
also provides total isolation between the DR-
switch
and external equipment.

Maximum external supply voltage

must not exceed +24V DC. Maximum current
sink through any open collector output must
not exceed 200mA.

A few examples are shown in the diagram
here. For further advice contact Allen & Heath
technical support.

V

+ -

G

+ - +

2

1

LED INDICATORS

+10V DC

SUITABLE RESISTORS

+ -

3

V

+ -

G

+ - +

6

5

+ -

7

+ -

4

+ -

8

V

+ -

G

+ - +

10

9

+ -

11

+ -

12

V

+ -

G

+ - +

14

13

+ -

15

+ -

16

+10V

OPEN COLLECTOR

OPTO

INTERNAL DR-switch CIRCUIT

(1 OF 4 SHOWN)

LOW CURRENT 12V BULBS

LOW VOLTAGE RELAY

+

-

TO EQUIPMENT

SUITABLE RESISTOR

+10V DC

+10V DC

V

-

G

+

V

-

G

+

-

+

V

-

G

+

CURRENT SINK

+V (+24V DC max)

GROUND

EXTERNAL POWER SUPPLY

DEVICE

200mA max