14 caution handling, Installation, Operation – Christie Digital Systems High Performance Xenon Lamp CDXL User Manual
Page 15: Storage, Disposal
14
Caution
Handling
When the lamp is soiled with fingerprints by touching glass envelope
•
with bare hand or dust, clean it with alcohol-soaked cloth. Otherwise
it could cause burst or short lamp life.
Do not subject the lamp to vibration or shock, since it is a glass product.
•
Otherwise it could burst or shorten lamp life.
Installation
Install the lamp in the correct polarity. Otherwise it could cause burst,
•
overheating of the lamp house or short lamp life.
Do not apply excessive stress such as twisting or bending when installing
•
the lamp. Otherwise it could cause an injury if it bursts.
Do not use any tools to tighten connections when fixing the lamp, use only
•
hands. Otherwise it could cause breakage.
Fix the lamp and its lead wire firmly to the terminals. Before fixing, make sure
•
that there is no rust, burning or discoloration where electrical connections
are made between the lamp and the lamp house. Otherwise it could cause
overheating by poor electrical connection.
Install the lamp with the protective cover. Be sure to remove the protective
•
cover from the lamp after installation.
Cover the lamp with the protective cover before removing the lamp from the
•
lamp house. Otherwise it could cause an injury if the lamp bursts.
Operation
Do not open the lamp house for at least ten (10) minutes after the lamp is turned
•
off. Otherwise it could cause an injury if it bursts.
Remove the lamp from the lamp house after making sure it has been turned
•
off for more than 15 minutes and the lamp and lamp house have cooled down.
Otherwise, it could cause an injury or burn if the lamp bursts.
Use a suitable lamp house and power supply (ballast). Operate a lamp in the range
•
of wattage designated.
Storage
Store the lamp under the following conditions.
Temperature: – 25 ~ 65°C Humidity: 20 ~ 95%RH without condensation
Disposal
The used lamp must be kept in the provided protective case until disposal by
•
breaking the glass part. Otherwise it could cause injury.
The lamp is filled with high pressure Xenon gas. Disposal without breaking
•
the glass part may result in lamp burst. Follow the instructions below to prevent
harmful repercussions:
WEAR A PROTECTIVE MASK, PROTECTIVE GLOVES AND A LONG
SLEEVED SHIRT WHEN HANDLING THE LAMP.
1.
The used lamp must be kept in the provided protective case;
the case must be securely locked by the metallic stopper.
2.
Place the used lamp in the protective case into the provided box.
Firmly attach the tape of the paper case to make certain the
case will not open if the lamp is dropped.
3.
From about one (1) meter in height, drop the provided box,
with the lamp and protective case inside, onto a hard floor.
4.
Shake the box to determine if the lamp is broken.
5.
Dispose of as industrial waste. Dispose separately where metal and
glass must be disposed of separately.