Output characteristics, Specification – Zippy RPU-6400F-RV2S User Manual
Page 20
INPUT
CHARACTERISTICS:
RPX-5300F
/
5400F-RV
VOLTAGE: 90 - 132 VAC / 180 - 260 VAC SWITCHABLE
FREQUENCY: 47 - 63 Hz
INPUT CURRENT: 3.0A / 1.5A PER UNIT (PARALLEL), 6.0A / 3.0A (ONE POWER)
INRUSH CURRENT: 40A MAX. FOR 110 VAC, 80A MAX. FOR 220VAC
OUTPUT CHARACTERISTICS:
OUTPUT CURRENT
REGULATION
OUTPUT
MIN. [A]
MAX. [A]
LOAD
LINE
+5V
7.0
30/50*
±
5%
±
1%
50mV
-5V
0
0.5/1.0*
-10%~+14%
±
1%
150mV
+12V
2.5
11
±
6%
±
1%
100mV
-12V
0
0.5/1.0*
-10%~+15%
±
1%
150mV
+3.3V
1.0
25/18*
±
5%
±
1%
50mV
+5VSB
0
800mA
±
5%
±
1%
50mV
RIPPLE & NOISE
MAX. [P-P]
OUTPUT
VOLTAGE
*
N / N: 300 / 400W
300W VERSION: +5V AND +3.3V TOTAL OUTPUT MAX: 150W
400W VERSION: +5V AND +3.3V TOTAL OUTPUT MAX: 250W
SPECIFICATION:
TEMPERATURE RANGE: OPERATING 0
-- 50
; STORAGE -20
-- 80
TRANSIENT RESPONSE: OUTPUT VOLTAGE RETURNS IN LESS THAN 1 ms MAX.
FOLLOWING A 50% LOAD CHANGE
HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 SECOND
INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
HUMIDITY: 10 ~ 90% RH
EFFICIENCY: 60% TYPICAL, AT FULL LOAD
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
OVER LOAD PROTECTION: 130 ~ 150% MAX.
OVER VOLTAGE PROTECTION: +5V
5.5V ~ 7.0V, 3.3V: 3.8V ~ 4.5V
OVER CURRENT PROTECTION: SHORT CIRCUIT
ALARM METHOD: 1. AUDIO ALARM, 2. FAULT LED, 3. POWER DEFECTIVE SIGNAL
EMI NOISE FILTER: AC INPUT LINE FILTER FOR FCC CLASS B ON EACH POWRE
UNIT ARE AVAILABLE UPON ORDER
SAFETY: UL / CSA / TÜV APPROVAL
HOT-SWAPPABLE / HOT-PLUGGABLE CAPABILITY
DIMENSION: REFER TO THE DRAWING
REDUNDANCY: BALANCE SHARE LOAD METHOD
REMOTE ON/OFF: OPERATE BY A REMOTE (SELV) SIGNAL
5VSB STANDBY VOLTAGE: A LOW CURRENT CONTINUOUS 100mA SOURCE
AT +5V, ALWAYS ENABLE, CAN NOT BE SWITCHED OFF
21