Zippy RPU-6400F-RV2S User Manual
Page 18
INPUT CHARACTERISTICS:
RPX - 4300 / 5300
* VOLTAGE : 90 - 132 VAC OR 180 - 264 VAC SWITCHABLE
* FREQUENCY : 47 - 63 HZ
* INPUT CURRENT : 3.4 A / 1.7 A PER UNIT (PARALLEL)
6.2 A / 3.1 A ( ONE POWER SUPPLY )
* INRUSH CURRENT : 40 A MAX. FOR 115 VAC,
80 A MAX. FOR 230 VAC ( ONE POWER SUPPLY)
OUTPUT CHARACTERISTICS :
OUTPUT
CURRENT
REGULATION
OUTPUT
MIN. (A)
MAX. (A)
LOAD
LINE
7.0
25/50*
3.0**
10/20**
12
2.5
14/28*
+ / - 5%
+ / - 1%
100 mV
-5V
0
0.5
+ / - 10%
+ / - 2%
150 mV
-12
0
0.5
+ / - 10%
+ / - 2%
150 mV
3.3***
3
20
+ / - 5%
+ / - 1%
50 mV
OUTPUT
VOLTAGE
RIPPLE & NOISE
MAX. (P-P)
5
50 mV
+ / - 5%
+ / - 1%
* : PEAK FOR 1 MINUTE
** : UNDER WITH 3.3 V OUTPUT CONDITION
*** : 3.3 OUTPUT IS OPTIONAL
THE MAX. TOTAL OUTPUT OF +5V AND +3.3V IS 125W.
* TEMPERATURE RANGE : OPERATING 0
°
C --- 50
°
C, STORAGE -20
°
C --- 80
°
C
* TRANSIENT RESPONSE : OUTPUT VOLTAGE RETURNS IN LESS THAN 1 ms
MAX. FOLLOWING A 50 % LOAD CHANGE
* HOLD UP TIME : 16 ms MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE
* DIELECTRIC WITHSTAND : INPUT TO FRAME GROUND 1500 VAC FOR 1 SEC.
* HUMIDITY : 10 - 90 % RH
* EFFICIENCY : 70 % TYPICAL AT FULL LOAD
* POWER GOOD SIGNAL : ON DELAY 100 ms TO 500 ms, POWER FAIL
≥ 1 ms
* OVERLOAD PROTECTION : 110 - 150 % MAX. ( POWER UNIT )
* OVER VOLTAGE PROTECTION : + 5V OUTPUT: 5.5 V --- 6.5 V
* SHORT PROTECTION
* ALARM METHOD: 1) AUDIO ALARM 2) FAULT LED 3) POWER DEFECTIVE SIGNAL
* EMI NOISE FILTER: AC INPUT LINE FILTER FOR FCC CLASS B ON EACH UNIT
* SAFETY: EACH POWER UNIT ARE UL / CSA / TÜV APPROVAL
* HOT-SWAPPABLE & HOT-PLUGGABLE CAPABILITY
* DIMENSION : REFER THE DRAWING
* REDUNDANCY: BALANCED SHARE LOAD METHOD
19