Output characteristics – Zippy R2G-6350P User Manual
Page 16
INPUT CHARACTERISTICS:
R2G-6300P
VOLTAGE: 95 ~264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 Hz
INPUT CURRENT: 6.0 / 3.0 A FOR 115 / 230 VAC
INRUSH CURRENT: 60A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE
OUTPUT CHARACTERISTICS:
OUTPUT CURRENT
REGULATION
OUTPUT
MIN.[A] MAX.[A] PEAK(A)
LOAD
LINE
5V
3.0
32
±
5%
±
1%
50mV
12V
2
16
20
±
6%
±
1%
120mV
-5V
0.05
0.5
±
10%
±
1%
120mV
-12V
0.05
0.8
±
10%
±
1%
150mV
3.3V
1.0
20
±
5%
±
1%
50mV
+5VSB
0.1
1.5
±
5%
±
1%
50mV
OUTPUT
VOLTAGE
RIPPLE & NOISE
MAX. [P-P]
REMARKS: TOTAL CURRENT OF +5V AND + 3.3V NOT EXCEED 32 A
TOTAL +5V AND 3.3V AND 12V POWER NOT EXCEED 285 W
.
TEMPERATURE RANGE : OPERATING 0
0
C --- 40
0
C, STORAGE –20
0
C --- 80
0
C
HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE
INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE
EFFICIENCY: 63% TYPICAL, AT FULL LOAD
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
OVER LOAD PROTECTION: 110 ~ 160% MAX.
OVER VOLTAGE PROTECTION:
+5V
5.7V ~ 6.5V, 3.3V
3.9 ~ 4.3V, 12V
13.3 ~ 14.3V
. OVER CURRENT PROTECTION : 5V, 12V, 3.3V 130% +/- 20% AT FULL LOAD
-5V, -12V SHORT CIRCUIT
EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950
REMOTE ON / OFF CONTROL
FAULTY ALARM METHODS : LED, BUZZER, TTL SIGNAL
HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION
BALANCE LOAD SHARING DESIGN
REMOTE SENSING DESIGN
ISOLATION: BUILT-IN IN THE POWER MODULE
MEET IEC-1000-3-2 CLASS D ( ACTIVE PFC )
DIMENSION: 82(H) X 101(W) X 300 (D) mm W Rear DC Fan
82(H) X 101(W) X 276 (D) mm W/O Rear DC Fan
COOLING : TWO 40 mm DC FANS ( ONE IN EACH MODULE )
ONE 80 mm DC FAN (REAR SIDE)
* I2C FEATURE (OPTIONAL )
Revision: A05