Output characteristics – Zippy R2T-6460P User Manual
Page 19
INPUT CHARACTERISTICS: MR3/R3U/R2T-6460P
VOLTAGE: 95 ~ 264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 Hz
INPUT CURRENT: 9.0 / 4.5 A FOR 115 / 230 VAC
INRUSH CURRENT: 35A / 70A MAX. FOR 115 / 230 VAC PER POWER MODULE
OUTPUT CHARACTERISTICS:
OUTPUT CURRENT
REGULATION
OUTPUT
MIN.[A] MAX.[A] PEAK(A)
LOAD
LINE
5V
2.0
50
±
5%
±
1%
50mV
12V
2
32
±
5%
±
1%
100mV
-5V
0.1
1
±
10%
±
1%
120mV
-12V
0.1
1
±
10%
±
1%
150mV
3.3V
1.0
28
±
5%
±
1%
50mV
+5VSB
0.1 3.0
±
5%
±
1%
50mV
OUTPUT
VOLTAGE
RIPPLE & NOISE
MAX. [P-P]
REMARKS: TOTAL CURRENT OF +5V AND + 3.3V NOT EXCEED 50 A
TOTAL +5V AND 3.3V AND 12V POWER NOT EXCEED 460 W
.
TEMPERATURE RANGE : OPERATING 0
0
C --- 40
0
C, STORAGE –20
0
C --- 70
0
C
HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE
DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE
INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE
EFFICIENCY: 63% TYPICAL, AT FULL LOAD
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
OVER LOAD PROTECTION: 110 ~ 160% MAX.
OVER VOLTAGE PROTECTION:
+5V
5.7V ~ 6.5V, 3.3V
3.9 ~ 4.3V, 12V
13.3 ~ 14.3V
. DUAL EMI NOISE INLET FILTER: FCC CLASS B, CISPR22 CLASS B
SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950
REMOTE ON / OFF CONTROL
FAULTY ALERT METHODS : LED, BUZZER, TTL SIGNAL
HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION
2 + 1 BALANCE LOAD SHARING DESIGN ON 5/12/3.3V CHANNEL
REMOTE SENSING DESIGN
ISOLATION: BUILT-IN IN THE POWER MODULE
MEET IEC-1000-3-2 CLASS D ( ACTIVE PFC )
DIMENSION: 82(H) X 150(W) X 230/254 (D) mm (MR3)
82(H)X127(W)X230/254(D) mm (R3U)
83(H)x127(W)x230/254(D) mm (R2T)
COOLING : THREE 40 mm DC FANS ( ONE IN EACH MODULE )
ONE 80 mm DC FAN ( REAR SIDE )
I2C FEATURES ( OPTIONAL – MR3 ONLY )
Revision: A03