TECHNICAL DATA

DIMENSIONS
Height

900 - 915mm

Width

1000mm

Depth

600mm (excluding door handles)

GENERAL
Gas connection

Rp

1

/

2

(

1

/

2

” BSP female)

Pressure test point

Hotplate burner injector

Gas rate adjustment

None

Aeration adjustment

None

Electrical connection

230/240V a.c. 50Hz.

Total electrical heat input

7.38 kW

INSTALLATION INSTRUCTIONS

HEAT INPUT

HEAT

INPUT

BURNER

INJECTOR

HEAT

INPUT

GAS RATE

INJECTOR

Cat II

2H3+

G20 at 20 mbar

Cat II

2H3+

G30 at 28 - 30 mbar

G31 at 37 mbar

240V a.c.

2.66 kW

TWIN GRILL

2.50 kW

L/H OVEN

2.00 kW

R/H OVEN

0.22 kW

WARMING
DRAWER

2.0 kW

1.80 kW

HOTPLATE
Front Left

102

3.0 kW

HOTPLATE
Rear Left

128

HOTPLATE
Wok Outer
Centre Front

2 x 114

5.10 kW

2.80 kW

4.75 kW

HOTPLATE
Wok Inner
Centre Front

70

65

82

2 x 70

44

130g/hr

205g/hr

1.65 kW

1.50 kW

HOTPLATE
Front Right

88

1.65 kW

HOTPLATE
Rear Right

88

1.50 kW

60

60

110g/hr

1.02 kW

1.00 kW

HOTPLATE
Auxiliary
Centre Rear

72

50

75g/hr

110g/hr

345g/hr

28