• Inspect tool cords periodically and if damaged, have them

repaired by an authorized service facility.

• Green (or green and yellow) conductor in cord is the

grounding wire. If repair or replacement of the electric cord
or plug is necessary, do not connect the green (or green
and yellow) wire to a live terminal.

• Where a 2-prong wall receptacle is encountered, it must be

replaced with a properly grounded 3-prong receptacle
installed in accordance with National Electric Code and
local codes and ordinances.

WARNING:

This work should be performed by a qualified

electrician.
A temporary 3-prong to 2-prong grounding adapter (see
Figure 41) is available for connecting plugs to a two pole out-
let if it is properly grounded.

• Do not use a 3-prong to 2-prong grounding adapter unless

permitted by local and national codes and ordinances.

• (A 3-prong to 2-prong grounding adapter is not permitted

in Canada.) Where permitted, the rigid green tab or termi-
nal on the side of the adapter must be securely connected
to a permanent electrical ground such as a properly
grounded water pipe, a properly grounded outlet box or a
properly grounded wire system.

• Many cover plate screws, water pipes and outlet boxes are

not properly grounded. To ensure proper ground, grounding
means must be tested by a qualified electrician.

EXTENSION CORDS

• The use of any extension cord will cause some drop in

voltage and loss of power.

• Wires of the extension cord must be of sufficient size to

carry the current and maintain adequate voltage.

• Use the table to determine the minimum wire size (A.W.G.)

extension cord.

• Use only 3-wire extension cords having 3-prong grounding

type plugs and 3-pole receptacles which accept the tool plug.

• If the extension cord is worn, cut, or damaged in any way,

replace it immediately.

Extension Cord Length (120V Operation)

Wire Size A.W.G.

Up to 25 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Up to 50 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
NOTE: Using extension cords over 50 ft. long is not
recommended.

ELECTRICAL CONNECTIONS
WARNING:

Make sure unit is off and disconnected from

power source before inspecting any wiring.
The saw is prewired for use on a 120 volt, 60HZ power supply.
The power lines are inserted directly onto the switch. The
green ground line must remain securely fastened to the frame
to properly protect against electrical shock.

240 VOLT OPERATION

• To use the saw with a 240V, single-phase power supply,

have a qualified electrician attach a 240 volt, 15A 3-prong
plug onto saw line cord and install the proper connectors
and receptacles to power supply.

• See wiring diagram (Figure 42) for wiring instructions.

OPERATION

Refer to Figures 43-52, pages 15-18.

DESCRIPTION

The Craftsman 10

″ Model Number 218330 contractor saw

offers precise cutting performance for all woods up to 3

1

8

thick. The saw is designed for the professional user and is
ruggedly constructed for continuous service. The 10

″ Saw is

recommended for use with a 10

″ blade.

The saw features an extra large cast iron table. Saw body has
on board storage for push stick, miter gauge, rip fence and
saw blades. Saw is equipped with a riving knife and a clear
acrylic blade guard with anti-kickback feature. Cabinet is con-
structed of heavy gauge welded steel, totally enclosed and is
ported for a 4

″ vacuum hose.

Rip Fence Assembly features a heavy-duty precision rip fence
that is designed for simple and one-hand maneuverability.
Front rail is calibrated in inches and millimeters with a magni-
fied window for close tolerances.

SPECIFICATIONS

Capacity with 10

Blade:

Depth of cut at 90° . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1

8

Maximum tilt angle of arbor (left) . . . . . . . . . . . . . . . . . . . . 45°
Depth of cut at 45° . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

3

16

Max. cut right of blade with rip fence . . . . . . . . . . . . . . . . . 30

Max. cut left of blade with rip fence . . . . . . . . . . . . . . . . . . 13

Saw Dimensions:
Table height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

3

8

Cabinet depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Cabinet width. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19½

Table area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

5

16

x 20

3

16

Front of table to blade . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

3

4

14

Figure 42 - Wiring Schematic

3

3

1

120V

240V

1

2

4

2

4

L1

L2

L1

L2

Figure 41 - 2-Prong Receptacle with Adapter

Make Sure
This Is
Connected To
A Known
Ground

2-Prong Receptacle

Grounding Lug

Adapter

3-Prong Plug