Wine-Mate HZD-DE Series User Manual

Page 23

background image

- 22 -

high or not
cooling and
running
continually


b. Cellar too large
c. Ambient temperature too high
d. Exhaust

restricted




e. Malfunctioning

fans


f.

Evaporator or condenser airflow

g. Dirty

Condenser

h. Iced

evaporator

i. Refrigeration

system

restriction

j. Refrigerant

leak

k. Undercharge or overcharge
l. Failed

components

opening

b. Check for excessive size
c. Check installation location
d. Leave minimum 3 feet clearance for

the hot air exhaust side and leave
minimum 1 foot clearance for the
fresh air intake side

e. Check for both evaporator and

condenser fans

f. Check for air restrictions, air short-

circulation, grille directions

g. Clean

condenser

h. Defrost and reset temperature
i. Call

service

j. Call

service

k. Call

service

l. Check compressor windings, start

relay and overload protector

7. Unit running

too long

a. Improper cellar insulation & seal

b. Cellar too large
c. Ambient temperature higher >

90

°

F

d. Exhaust restricted



e. Dirty Condenser
f. Improper condenser air flow

a. Check insulation, gasket and door

opening

b. Check for excessive size
c. Check for installation location

d. Leave minimum 3 feet clearance for

the hot air exhaust side and leave
minimum 1 foot clearance for the
fresh air intake side

e. Clean condenser
f. Check for fan and air short

circulation

8. Fan motor

running but
compressor
not running

a. Post-compressor fan running

mode

b. Incorrect or loose wirings
c. Failed

components


d.

Liquid refrigerant in the
compressor

a. Check fan running time FON

b. Check all wirings and connections
c. Check start relay, start capacitor,

overload protector, compressor.

d. Call

service.

9. Compressor

running but
fan not
running

a. Fan blade stuck
b. Incorrect or loose wirings
c. Failed

motors

a. Check for proper clearance
b. Check all wirings
c. Call

service

10.Temperature

high,
compressor
stopping
and starting
but very
short
running time

a. Failed

components


b. Improper

condenser

airflow

c. Dirty

condenser

d. Overcharge of refrigerant
e. Discharge or suction pressure

too high

a. Check compressor windings, start

relay and overload protector.

b. Check for condenser fan
c. Clean

condenser

d. Call service for removing refrigerant
e. Call service for information

11.Fan running

too long

a.

Post-compressor fan running
mode for humidity modulation

a. Reset FON

12.Temperature

a. Low temperature setting

a. Raise the setting