Alarms – WineKeeper MAGNUM Series User Manual
Page 12

10
Alarms
The cooling unit has both an audible notification and a visual alarm indicator (shown in “red” on the control
panel) that are activated when an alarm is triggered. Please note: the HA and LA alarms are disabled during the
first 23 hours of operation after the cooling unit is plugged in and/or turned on.
The control panel also will flash a code for each alarm, as follows:
Alarm Code
P1, P3
HA
HA2
LA
LA2
What it Means
Probe Failure
The temperature inside the cab-
inet is too warm (above 70°F for
more than 1 hour)
The condenser temperature is too
high (above 140°F for 2 hours)
The temperature inside the cabi-
net is too cold (below 45°F)
The temperature at the condenser
coils (outside the cabinet) has
dropped below the alarm
temperature setting
What to do
Call WineKeeper at 855.511.5113
Check seals, check if door was left open,
lower the ambient temperature
Check for appropriate installation,
ventilation, ambient conditions, and
cooling capacity
Clean the condenser coils
Check for obstructions to the intake and/or
exhaust vents
Check that the condenser fan is operating
Raise the ambient temperature;
Make sure the cold air discharge has
sufficient clearance for the air to circulate
Raise the “Minimum Set Point”
Call WineKeeper at 855.511.5113