beautypg.com

Vintage Cellars Thru Wall Fan User Manual

Warning, Introduction, One year warranty

background image

PLEASE READ THESE INSTRUCTIONS BEFORE

STARTING INSTALLATION

The ThruWall can be mounted in any normal drywall or paneled stud construc-

tion wall up to 6-1/2” maximum total thickness. Depending on your needs,

the ThruWall can be installed high or low on the wall. Please note that warm

air rises, thus is found near the ceiling. Conversely, cold air falls and is found

near the floor. The temperature of the air near the ceiling may be as much as

10°F to 15°F higher than near the floor. Start by making sure that there are NO

studs, water, drain, electrical or other obstruction in the wall where you wish to

install the unit. The power cord of the ThruWall is 10ft long, please verify that

the power cord will reach a 110 Volt AC outlet. The use of extension cords is not

recommended. Please see the airflow direction label on the housing.

The grilles of your ThruWall fan may be painted to suit any decor. Thoroughly

wash the grilles with mild household detergent, dry completely, and spray with

a quality, fast dry, spray paint.

When installing your ThruWall fan, the cutouts must be accurate.

IN THE CARTON YOU WILL FIND:

(1) Telescoping metal sleeve with plastic grill attached.

(1) Telescoping metal sleeve without grill attached.

(1) Loose grille.

(6) #6 Screws.

(6) Wall Anchors.

ONE YEAR WARRANTY

Subject to the following limitations, WhisperKOOL warrants that the ThruWall

Fan will, for 1 (one) year from date of original retail purchase, but not exceeding

two years from date of manufacture, remain free from appearance of defects

in workmanship or materials. This warranty is subject to the following limita-

tions: (a) manufacturer’s liability is limited to the replacement or repair of the

unit, as decided by the manufacturer; (b) a defective unit must be returned,

prepaid, with proof of purchase; and (c) this warranty does not apply to defects

resulting from the alteration, abuse, accidental damage, unauthorized repair, or

misuse of the unit. This warranty is given in lieu of all other warranties, guaran-

tees, and conditions on manufacturer’s part, and the manufacturer shall have

no tortious or other liability in respect to this ThruWall Fan.

Actual product appearance may differ from illustrations.

WhisperKOOL reserves the right to modify any or all of its products’ features,
designs, components and specifications without notice.

INSTALLATION

1.

Place the metal sleeve (without the grille attached) against the wall with

the flanged edge facing you. Trace the pipe on the outside with a pencil

to mark the cutout. (Figure 1)

WhisperKOOL

1738 E. Alpine Ave. Stockton, CA 95205

1(800) 343-9463

www.whisperkool.com

INTRODUCTION

The ThruWall fan moves air from room to room quietly and efficiently. Simple

to install in any frame wall from 3-1/2” to 6-3/4” thick. A high quality Thermally

Protected motor with balanced fan blade moves up to 200 CFM. Move heated

or cooled air between rooms.

The fans are carefully packaged, inspected and tested to insure safe operation

and delivery. When you receive your fans, examine it carefully to determine

that there are no broken or damaged parts that may have occurred during

shipment. If damage has occurred, make notation and notify WhisperKool.

They will assist you in replacement or repair, if required.

READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPER-

ATE OR SERVICE THE THRUWALL ROOM TO ROOM FAN™. KNOW THE FAN

APPLICATION, LIMITATIONS AND POTENTIAL HAZARDS. PROTECT YOURSELF

AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY

WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY

DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. INSTALLATION AND

CONNECTIONS ARE TO BE MADE BY A QUALIFIED PERSON.

IMPORTANT NOTICE

WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE

THIS FAN WITH A SOLID STATE SPEED CONTROL DEVICE.

With the use of any electrical appliance, it is important to observe all basic

precautions to minimize the risk associated with use, such as electrical shock,

fire, or injury to persons.

Read these instructions before using your ThruWall Room to Room Fan™.

If you have doubts or are unfamiliar with this type of installation work, seek the

services of a qualified electrician. WhisperKOOL assumes no responsibility for

installation of thru ThruWall Fan ™ Do not use a variable speed controls with

this product. WhisperKOOL does not provide electrical connection information.

For your safety and protection follow all instructions and adhere to applicable

building and/ or electrical codes.

Not for bathroom use.

Do not use in wet locations.

Do not use in a window.

Do not install in fire rated walls.

Route the electric cord so that it cannot be tripped over.

Use only a grounded wall outlet.

WARNING -

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING:

1. Installation work and electrical wiring must be done by qualified person(s)

in accordance with all applicable codes and standards, including fire-rated

construction.

2. When cutting or drilling into wall or ceiling, do not damage electrical wiring

or other hidden utilities.

3. Not to be used with any solid state speed control.

Operation Instructions:

The ThruWall is equipped with a two speed motor. There is a three position

switch on the output side of the fan. The switches: position (I) is low speed,

center (O) off, and position (II) is high speed.

WARNING

!

!

Figure 1