Page 5/7

Vetter Collection tubs 0.3 bar / 4.35 psi

2

1

3

Fold the collecting tub in the way, that the air can escape (Folding to the
direction of the inflation connection). Any remaining air can be removed
with a vacuum adaptor (Item No.: 1700018300) in combination with an
construction-site compressor adaptor (Item No.: 1600012000).
Connect the construction-site compressor adaptor (1) to the coupling
of the vacuum adaptor (2) and turn it interlocking. Then tighten the
screwable part of t the vacuum adaptor. Now connect the construction-
site compressor adaptor to the support frame. Attach the quick-action
coupling (3) to the connection hose of the pressure regulator and open
the hand valve of the pressure regulator slowly.

After deflation and before packing, the valve

must be unlocked again in order to guarantee

perfect inflation when it is next used!

4.5 Care and Maintenance

The collecting tub and its fittings are to be cleaned after use. Cleaning
of the collecting tub is normally made using warm water together with
a soap solution and dried at room temperature. Store in cool dry place
and avoid sun exposure.

5.

Inspections

The inflation fittings and the collecting tub are to be checked for a per-
fect and orderly condition each time before and after use:

9

The collecting tub is free of damage, e.g. tears, cuts, piercings, splits,

hard or soft areas caused by chemical or thermal effects.

9

The insertion tub is free of damage, e.g. tears, cuts, piercings, splits,

hard or soft areas caused by chemical or thermal effects.

9

Visual and operational check of the pressure reduction regulator.

6.

Taking the product out of operation

In case the collection tubs are taken out of operation then this must be
disposed of as special waste. If required, the manufacturer can supply
you with more detailed information regarding this.